{"created":"2023-05-15T14:39:09.206562+00:00","id":53784,"links":{},"metadata":{"_buckets":{"deposit":"f41fb373-c0a3-4176-b291-3cb41576f978"},"_deposit":{"created_by":1,"id":"53784","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53784"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053784","sets":["2"]},"author_link":["548914","548911","548912","548913","548915"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"158","bibliographicPageStart":"157","bibliographic_titles":[{"bibliographic_title":"日本加速器学会年会・リニアック技術研究会"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"6MeV/u Argon beam stacking experiment using electron cooling (EC) has been executing in Heavy Ion Medical Accelerator in Chiba (HIMAC), in order to enhance beam quality, intensity and expand application. Beam loss has been observed at certain intensity due to rapid growth of vertical oscillation. Technique of analog feedback-damping (FBD) is introduced for suppressing the vertical oscillation and for increasing storage beam intensity.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野田, 耕司"}],"nameIdentifiers":[{"nameIdentifier":"548911","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鳥飼, 幸太"}],"nameIdentifiers":[{"nameIdentifier":"548912","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渋谷, 真二"}],"nameIdentifiers":[{"nameIdentifier":"548913","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548914","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鳥飼 幸太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548915","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-12-27"},"publish_date":"2006-12-27","publish_status":"0","recid":"53784","relation_version_is_last":true,"title":["INCREASE OF STORAGE BEAM INTENSITY BY VERTICAL FEEDBACK DAMPING IN HIMAC"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:08:39.133943+00:00"}