{"created":"2023-05-15T14:39:08.544433+00:00","id":53769,"links":{},"metadata":{"_buckets":{"deposit":"91b73709-ba03-4926-9a15-7a721edb0241"},"_deposit":{"created_by":1,"id":"53769","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53769"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053769","sets":["2"]},"author_link":["548756","548753","548754","548755"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"130","bibliographicPageStart":"128","bibliographicVolumeNumber":"A SPECIAL ISSUE","bibliographic_titles":[{"bibliographic_title":"Journal of Radiation Protection Bulletin"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Our purpose in this study is to develop an in-vivo monitor with compact and portable which can be used on the scene. This monitor, which consists of a Ge detector and a guard detector, can identify and quantify the nuclei by applying the anti-coincidence method in spite of considerable background. In order to determine the Germanium crystal size and optimize a dewar size of a Ge detector, the fundamental property data of cooling system is needed in the design. In the present study, a characteristic test for Ge detectors has been carried out to examine the property of cooling system, such as the duration for which the temperature of Germanium crystal reached below -150 degrees and LN2 consumption. From the obtained results, it was found that the Ge detector will be used for responding to radiation emergency accidents.","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1004-6356","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Eunjoo, Kim"}],"nameIdentifiers":[{"nameIdentifier":"548753","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuki, Tosikazu"}],"nameIdentifiers":[{"nameIdentifier":"548754","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金 ウンジュ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548755","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 敏和","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548756","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Development of a Portable in vivo Monitor for Radiation Emergency Accidents","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a Portable in vivo Monitor for Radiation Emergency Accidents"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-11-30"},"publish_date":"2006-11-30","publish_status":"0","recid":"53769","relation_version_is_last":true,"title":["Development of a Portable in vivo Monitor for Radiation Emergency Accidents"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:08:49.338465+00:00"}