{"created":"2023-05-15T14:39:07.872212+00:00","id":53754,"links":{},"metadata":{"_buckets":{"deposit":"a86541bf-1e10-46ab-9c6f-2dc5eafdb1b2"},"_deposit":{"created_by":1,"id":"53754","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53754"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053754","sets":["2"]},"author_link":["548621","548622","548619","548618","548617","548620","548623"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"54","bibliographicPageStart":"51","bibliographic_titles":[{"bibliographic_title":"電子情報通信学会技術研究報告"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"MRI(Magnetic Resonance Imaging:磁気共鳴画像法)は、強い静磁界中におかれた生体にパルス状電磁波を照射することによって生じるNMR(Nuclear Magnetic Resonance:核磁気共鳴)信号を受信し、生体内部を画像化する方法である。近年、妊娠女性がMRIを利用した際における、RFコイルから発せられる電磁波によるSAR(Specific Absorption Rate:比吸収率)の評価が求められている。本稿では、もっとも基本的な構造を有するバードにより、妊娠女性腹部および胎児におけるSARを算出した。","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0913-5685","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"齊藤, 一幸"}],"nameIdentifiers":[{"nameIdentifier":"548617","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤, 公一"}],"nameIdentifiers":[{"nameIdentifier":"548618","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平, 博夫"}],"nameIdentifiers":[{"nameIdentifier":"548619","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"548620","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"齊藤 一幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548621","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤 公一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548622","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平 博夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548623","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"リアルな妊娠女性数値モデルを用いたMRI用RFコイルによる胎児内SAR","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"リアルな妊娠女性数値モデルを用いたMRI用RFコイルによる胎児内SAR"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-08-21"},"publish_date":"2006-08-21","publish_status":"0","recid":"53754","relation_version_is_last":true,"title":["リアルな妊娠女性数値モデルを用いたMRI用RFコイルによる胎児内SAR"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:08:59.931178+00:00"}