{"created":"2023-05-15T14:39:07.512240+00:00","id":53746,"links":{},"metadata":{"_buckets":{"deposit":"17a7ba4b-42fd-4227-a1e1-585e634d2b06"},"_deposit":{"created_by":1,"id":"53746","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53746"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053746","sets":["2"]},"author_link":["548554","548551","548556","548552","548557","548558","548555","548553","548549","548550"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"70","bibliographicPageStart":"67","bibliographicVolumeNumber":"8","bibliographic_titles":[{"bibliographic_title":"Proceedings of the Symposium on Accelerator and Related Technology for Application"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Neutrons produced through fragmentation reactions in charged particle may cause significant acute or late biological effects to a patient's body. To estimate these effects, we adopted Bonner spheres that could measure the fluence and the energy distributions of neutrons without directivity. From the xperiments, we found that the spectra from Bonner spheres under the existence of high-energy charged particles and neutrons are complicated by background is likely the charged-particles through fragmentation reactions.","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1344-4514","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松井, 祐樹"}],"nameIdentifiers":[{"nameIdentifier":"548549","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤, 成弘"}],"nameIdentifiers":[{"nameIdentifier":"548550","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡部, 恵理子"}],"nameIdentifiers":[{"nameIdentifier":"548551","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井, 達明"}],"nameIdentifiers":[{"nameIdentifier":"548552","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野, 俊之"}],"nameIdentifiers":[{"nameIdentifier":"548553","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松井 祐樹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548554","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤 成弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548555","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡部 恵理子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548556","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548557","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野 俊之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"548558","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"治療用高エネルギー粒子場におけるボナー球の応答特性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"治療用高エネルギー粒子場におけるボナー球の応答特性"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-07-19"},"publish_date":"2006-07-19","publish_status":"0","recid":"53746","relation_version_is_last":true,"title":["治療用高エネルギー粒子場におけるボナー球の応答特性"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:09:05.441407+00:00"}