{"created":"2023-05-15T14:39:03.830114+00:00","id":53662,"links":{},"metadata":{"_buckets":{"deposit":"f52e4f54-5706-413f-9838-7629b110d7d6"},"_deposit":{"created_by":1,"id":"53662","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53662"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053662","sets":["2"]},"author_link":["547714","547713","547710","547715","547712","547711"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"99","bibliographicPageStart":"96","bibliographicVolumeNumber":"6","bibliographic_titles":[{"bibliographic_title":"Proceedings of the Workshop on Environmental Radioactivity (KEK Proceedings)"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We descirbe a chemical separation procedure for determination of Ra-226 in natural water samples with high-resolution ICP-MS (HR-ICP-MS). THe proposed procedure is focused on the application of ion exchange and extraction chromatography for pre-concentration and separation of Ra from water samples. It was clear that the sensitivity of HR-ICP-MS was sufficient for Ra-226 determination in natural water after selective extraction of the analyte.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tolmachev, Sergei"}],"nameIdentifiers":[{"nameIdentifier":"547710","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"547711","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"547712","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tolmachev Sergei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"547713","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"547714","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"547715","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Application of ion exchange and extraction chromatography for Ra-226 determination in natural waters using HR-ICP-MS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Application of ion exchange and extraction chromatography for Ra-226 determination in natural waters using HR-ICP-MS"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-05-29"},"publish_date":"2006-05-29","publish_status":"0","recid":"53662","relation_version_is_last":true,"title":["Application of ion exchange and extraction chromatography for Ra-226 determination in natural waters using HR-ICP-MS"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:10:03.654105+00:00"}