{"created":"2023-05-15T14:38:31.277043+00:00","id":52991,"links":{},"metadata":{"_buckets":{"deposit":"09a1cc03-25b2-41fe-88b0-d43ce864fabf"},"_deposit":{"created_by":1,"id":"52991","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"52991"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00052991","sets":["2"]},"author_link":["540541","540542","540544","540543"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"232","bibliographicPageStart":"231","bibliographic_titles":[{"bibliographic_title":"Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm2 and 2mm (depth).","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1589-6691","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hirai, Masaaki"}],"nameIdentifiers":[{"nameIdentifier":"540541","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"540542","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平井 正明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540543","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540544","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-01-29"},"publish_date":"2003-01-29","publish_status":"0","recid":"52991","relation_version_is_last":true,"title":["Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:17:43.957711+00:00"}