{"created":"2023-05-15T14:38:30.888611+00:00","id":52982,"links":{},"metadata":{"_buckets":{"deposit":"8d758ce1-51b3-4ff6-bdd8-983aafd0c216"},"_deposit":{"created_by":1,"id":"52982","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"52982"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00052982","sets":["2"]},"author_link":["540458","540460","540456","540461","540457","540459"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-11","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"492","bibliographicPageStart":"491","bibliographicVolumeNumber":"22","bibliographic_titles":[{"bibliographic_title":"医療情報学連合大会論文集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放医研では9年近くがんに対する炭素イオン線治療を行ってきた.その間、病院業務を支援するために、5つの異なるメーカのシステムが導入された.そこで、それぞれを発生源入力としてシステム間連携を行い、正確なデータを自動的に診療DBへ保管し、将来の電子カルテへ備える試みを行った.「システム構成」HISは、医事会計、オーダ処理、各業務支援および診療支援システムから構成されている.PACSは画像サーバとWEBサーバから構成され、診療DBと同じメーカが納入した.重粒子治療スケジューラ、照射管理システムおよび治療計画DBはそれぞれ異なるメーカが構築し、同じネットワーク上で稼働している.「システム間連携」患者基本情報、検査予約、生化学検査結果、投薬情報などは、診療支援システムを経由して診療DBへ取り込まれ、PACSにおける患者の確認、画像事前配信等に利用している.重粒子線治療予定や終了情報は、スケジューラから診療支援システムを経由して、診療DBへ記録される.また、治療条件は、治療計画DBから診療DBへ送られて、患者の検査歴、治療歴、病歴等と一元管理されている.診療DBはWEBブラウザー上で検索、詳細情報表示が可能である.「考察」病院ではそれぞれの業務ごとにデータが発生し、それをそのまま取り込んで一元管理できることが、最も正しいデータを容易に保管できることになる.そこで、システムの導入に際しては汎用のDBを使用し、画像データにDICOMを用いてシステム間連携した.照射終了後、入力の手間もなく正確で詳細な治療情報がDBへ蓄積された.「まとめ」診療DBは、現在、電子カルテとして利用する診療記録の90%を備えている.後は、医者の日常的な患者診療記録の入力法の確立が必要である.","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-8508","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"外山, 比南子"}],"nameIdentifiers":[{"nameIdentifier":"540456","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"上村, 幸司"}],"nameIdentifiers":[{"nameIdentifier":"540457","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田, 栄子"}],"nameIdentifiers":[{"nameIdentifier":"540458","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"外山 比南子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540459","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"上村 幸司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540460","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田 栄子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540461","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"病院情報システム間連携による発生源入力とデータの共有","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"病院情報システム間連携による発生源入力とデータの共有"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-01-16"},"publish_date":"2003-01-16","publish_status":"0","recid":"52982","relation_version_is_last":true,"title":["病院情報システム間連携による発生源入力とデータの共有"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:17:49.945159+00:00"}