{"created":"2023-05-15T14:38:12.869111+00:00","id":49312,"links":{},"metadata":{"_buckets":{"deposit":"7762ce48-d7c0-40e2-80e1-e2c9d831204b"},"_deposit":{"created_by":1,"id":"49312","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49312"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049312","sets":["1"]},"author_link":["497683","497684","497678","497680","497679","497682","497681"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"080015-3","bibliographicPageStart":"080015-1","bibliographicVolumeNumber":"2011","bibliographic_titles":[{"bibliographic_title":"AIP Conference Proceedings"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A prototype penning ionization gauge ion source has been developed for the installation of a 1-MeV compact ion microbeam system. The ion source must generate an ion beam with high brightness and low energy while consuming a minimum of low electric power consumption and fitting within a small size. A prototype penning ionization gage (PIG) ion source with two electromagnets, which generates an ion beam from high-density plasma in a small volume passing through a cathode with a small through-hole, was designed and constructed. The prototype PIG ion source generated low-energy hydrogen ion beams with the almost same distribution of ion species as a typical PIG ion source in the preliminary tests. The brightnesses of the ion beam with all ion species and proton beam were calculated and estimated to be 80 A/(m2SrV) and 8 A/(m2SrV) using the experimentally measured beam current and on the basis of the ion distribution, respectively. These values are sufficient for the installation in a compact ion microbeam system.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"96519","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5053370","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石井, 保行"}],"nameIdentifiers":[{"nameIdentifier":"497678","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大久保, 猛"}],"nameIdentifiers":[{"nameIdentifier":"497679","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柏木, 啓次"}],"nameIdentifiers":[{"nameIdentifier":"497680","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三宅, 善信"}],"nameIdentifiers":[{"nameIdentifier":"497681","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石井 保行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"497682","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大久保 猛","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"497683","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柏木 啓次","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"497684","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-12-13"},"publish_date":"2018-12-13","publish_status":"0","recid":"49312","relation_version_is_last":true,"title":["Development of a prototype PIG ion source with electric magnets for a compact ion microbeam system"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:20:11.794470+00:00"}