{"created":"2023-05-15T14:38:11.069453+00:00","id":49271,"links":{},"metadata":{"_buckets":{"deposit":"aa7f946b-b8f3-4488-8b88-6fc2e34c05d9"},"_deposit":{"created_by":1,"id":"49271","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49271"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049271","sets":["1"]},"author_link":["752957","752953","752956","752960","752950","752965","752969","752968","752948","752966","752958","752962","752955","752951","752949","752967","752947","752959","752952","752963","752961","752946","752954","752964"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"36","bibliographicPageStart":"31","bibliographicVolumeNumber":"20","bibliographic_titles":[{"bibliographic_title":"Journal of Applied Clinical Medical Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose: The QA team of the Japan carbon‐ion radiation oncology study group\n(J‐CROS) was organized in 2015 to enhance confidence in the accuracy of clinical\ndosimetry and ensure that the facility QA procedures are adequate. The team conducted\nonsite dosimetry audits in all the carbon‐ion radiation therapy centers in\nJapan.\nMaterials and Methods: A special phantom was fabricated for the onsite dosimetry\naudit. Target volumes such as the GTV, CTV, and PTV were contoured to the\nobtained CT images, and two plans with different isocenter depths were created.\nThe dose at the isocenter was measured by an ionization chamber, in the onsite\naudit and compared with the calculated dose.\nResults: For all the centers, the average of the percentage ratio between the measured\nand calculated doses (measured/calculated) was 0.5% (−2.7% to +2.6%) and\nthe standard deviation, 1.7%. In all the centers, the beams were within the set tolerance\nlevel of 3%.\nConclusions: The audit demonstrated that the dose at a single point in the water\nphantom was within tolerance, but it is a big step to say that all doses are correct.\nIn addition, this external dosimetry audit encouraged centers to improve the quality\nof their dosimetry systems.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Wiley Periodicals, Inc."}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"30387294","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1002/acm2.12465","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/acm2.12465","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1526-9914","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Mizuno, Hideyuki"}],"nameIdentifiers":[{"nameIdentifier":"752946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukumura, Akifumi"}],"nameIdentifiers":[{"nameIdentifier":"752947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"752948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonai, Shunsuke"}],"nameIdentifiers":[{"nameIdentifier":"752949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"752950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yusa, Ken"}],"nameIdentifiers":[{"nameIdentifier":"752951","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yanou, Toshihiro"}],"nameIdentifiers":[{"nameIdentifier":"752952","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suga, Masaki"}],"nameIdentifiers":[{"nameIdentifier":"752953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizota, Manabu"}],"nameIdentifiers":[{"nameIdentifier":"752954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Minohara, Shinichi"}],"nameIdentifiers":[{"nameIdentifier":"752955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"752956","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kamada, Tadashi"}],"nameIdentifiers":[{"nameIdentifier":"752957","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizuno, Hideyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752958","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukumura, Akifumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752959","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752960","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonai, Shunsuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752961","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752962","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yusa, Ken","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752963","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yanou, Toshihiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752964","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"suga, masaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752965","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizota, Manabu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752966","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Minohara, Shinichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752967","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752968","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kamada, Tadashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"752969","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"External dosimetry audit for quality assurance of carbon‐ion radiation therapy clinical trials","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"External dosimetry audit for quality assurance of carbon‐ion radiation therapy clinical trials"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-11-26"},"publish_date":"2018-11-26","publish_status":"0","recid":"49271","relation_version_is_last":true,"title":["External dosimetry audit for quality assurance of carbon‐ion radiation therapy clinical trials"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:53:26.287656+00:00"}