{"created":"2023-05-15T14:38:09.671305+00:00","id":49239,"links":{},"metadata":{"_buckets":{"deposit":"85af76b3-8635-47bf-ab5f-4870e93f2388"},"_deposit":{"created_by":1,"id":"49239","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49239"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049239","sets":["1"]},"author_link":["496801","496800","496797","496799","496798","496802"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"6","bibliographicPageStart":"2","bibliographicVolumeNumber":"136","bibliographic_titles":[{"bibliographic_title":"Fusion Engineering and Design"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The latest beta version of ENDF/B-VIII, ENDF/B-VIIIβ4 was released in February 2017 from the Cross Section Evaluation Working Group. We benchmarked the iron and concrete shielding experiments with 40 and 65 MeV neutrons at QST/TIARA by using ENDF/B-VII.1, JENDL-4.0/HE and ENDF/B-VIIIβ4 to investigate whether the 56Fe and 16O data in ENDF/B-VII.1 were properly improved in ENDF/B-VIIIβ4 or not. The drastic overestimation in the calculated result with ENDF/B-VII.1 was resolved in that with ENDF/B-VIIIβ4 in the iron experiment with 40 MeV neutrons, because of the revision of the non-elastic scattering cross section data of 56Fe in ENDF/B- VIIIβ4. However, the calculated result with ENDF/B-VIIIb4 significantly underestimated the measured one in the experiment with 65 MeV neutrons. The drastic overestimation in the calculated results with ENDF/B-VII.1 still appeared in those with ENDF/B-VIIIβ4 in the concrete experiments with 40 and 65 MeV neutrons, due to no improvement of 16O data particularly above 20 MeV in ENDF/B-VIIIβ4. We figured out that the effect of the 16O data replacement was very large and those of 28Si and 27Al data replacements were also not so small. The official release of ENDF/B-VIII should be produced based on this study.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier "}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.fusengdes.2017.11.021","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"権, セロム"}],"nameIdentifiers":[{"nameIdentifier":"496797","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"太田, 雅之"}],"nameIdentifiers":[{"nameIdentifier":"496798","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"落合, 謙太郎"}],"nameIdentifiers":[{"nameIdentifier":"496799","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"権 セロム","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"496800","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"太田 雅之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"496801","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"落合 謙太郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"496802","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ENDF/B-VIIIβ4 benchmark test with iron and concrete shielding experiments using 40 and 65 MeV neutrons at QST/TIARA","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ENDF/B-VIIIβ4 benchmark test with iron and concrete shielding experiments using 40 and 65 MeV neutrons at QST/TIARA"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-11-05"},"publish_date":"2018-11-05","publish_status":"0","recid":"49239","relation_version_is_last":true,"title":["ENDF/B-VIIIβ4 benchmark test with iron and concrete shielding experiments using 40 and 65 MeV neutrons at QST/TIARA"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:20:27.379205+00:00"}