{"created":"2023-05-15T14:38:07.723591+00:00","id":49195,"links":{},"metadata":{"_buckets":{"deposit":"3542c58e-52e0-4141-9a4d-578740855d8e"},"_deposit":{"created_by":1,"id":"49195","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49195"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049195","sets":["1"]},"author_link":["496353","496352"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"222","bibliographicPageStart":"219","bibliographicVolumeNumber":"6","bibliographic_titles":[{"bibliographic_title":"SPring-8/SACLA利用研究成果集"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"粘土鉱物に吸着したセシウムの化学結合状態に関する情報を得るため、粘土鉱物の一種であるバーミキュライトにセシウムを吸着させ、軟X線放射光を用いた高分解能光電子分光を試みた。粘土鉱物の絶縁性のために粉末試料の帯電は避けられず、試料の成分元素の光電子ピークを解析することは困難であるが、帯電シフトしない光電子ピークも観測されたことから、バーミキュライトに吸着したセシウムの内殻結合エネルギーを評価できることが分かった。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"公益財団法人高輝度光科学研究センター"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.18957/rr.6.2.219 ","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://user.spring8.or.jp/resrep/?p=9754"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://user.spring8.or.jp/resrep/?p=9754","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-6886","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"寺岡, 有殿"}],"nameIdentifiers":[{"nameIdentifier":"496352","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"寺岡 有殿","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"496353","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Cs 吸着バーミキュライトの軟 X 線放射光光電子分光","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Cs 吸着バーミキュライトの軟 X 線放射光光電子分光"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-10-04"},"publish_date":"2018-10-04","publish_status":"0","recid":"49195","relation_version_is_last":true,"title":["Cs 吸着バーミキュライトの軟 X 線放射光光電子分光"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:20:46.341696+00:00"}