{"created":"2023-05-15T14:38:07.632155+00:00","id":49193,"links":{},"metadata":{"_buckets":{"deposit":"eb464628-1e91-4cbc-8ff1-6d7c17bf293f"},"_deposit":{"created_by":1,"id":"49193","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49193"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049193","sets":["1"]},"author_link":["734204","734212","734215","734216","734207","734210","734213","734214","734211","734209","734206","734205","734208"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"434","bibliographicPageStart":"427","bibliographicVolumeNumber":"67","bibliographic_titles":[{"bibliographic_title":"RADIOISOTOPES"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a simple method for the long-term monitoring of the seasonal variation of the radiocaesium radioactivity in trees using commercially available integrating dosimeters. Experiments and Monte Carlo simulations were performed to assess whether the proposed dosimeter-based method could measure the seasonal variation. From the experimental results, the performance variation among individual dosimeters was found to be 1.6%, which is sufficiently small compared with the expected seasonal variation. Moreover, the simulation results indicated that the measured value of the dosimeter increased owing to the photons passing through a stem, and a correction factor was necessary to compensate the influence of photon absorption and scattering in stem. We suggested that the simple and easy dosimeter-based method could be useful to measure the seasonal variations of radioactivity in trees.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本アイソトープ協会"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3769/radioisotopes.67.427","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/radioisotopes/67/9/67_670904/_article","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0033-8303 ","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"栗田, 圭輔"}],"nameIdentifiers":[{"nameIdentifier":"734204","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山口, 充孝"}],"nameIdentifiers":[{"nameIdentifier":"734205","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長尾, 悠人"}],"nameIdentifiers":[{"nameIdentifier":"734206","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴井, 伸郎"}],"nameIdentifiers":[{"nameIdentifier":"734207","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尹, 永根"}],"nameIdentifiers":[{"nameIdentifier":"734208","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉原, 利一(電力中央研究所)"}],"nameIdentifiers":[{"nameIdentifier":"734209","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河地, 有木"}],"nameIdentifiers":[{"nameIdentifier":"734210","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kurita, Keisuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"734211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaguchi, Mitsutaka","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"734212","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagao, Yuuto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"734213","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzui, Nobuo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"734214","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yin, Yonggen","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"734215","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawachi, Naoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"734216","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of an Easy and Simple Method to Measure the Environmental Radioactivity in Trees with Efficient Personal Dosimeters","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of an Easy and Simple Method to Measure the Environmental Radioactivity in Trees with Efficient Personal Dosimeters"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-08-22"},"publish_date":"2018-08-22","publish_status":"0","recid":"49193","relation_version_is_last":true,"title":["Development of an Easy and Simple Method to Measure the Environmental Radioactivity in Trees with Efficient Personal Dosimeters"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T07:56:11.473501+00:00"}