{"created":"2023-05-15T14:38:07.497960+00:00","id":49190,"links":{},"metadata":{"_buckets":{"deposit":"9acf618f-cc22-44c9-a9ec-bf6dc0ccc6a8"},"_deposit":{"created_by":1,"id":"49190","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49190"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049190","sets":["1"]},"author_link":["804132","804131","804129","804134","804133","804127","804130","804128"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"573","bibliographicPageStart":"569","bibliographicVolumeNumber":"318","bibliographic_titles":[{"bibliographic_title":" Journal of Radioanalytical and Nuclear Chemistry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To assess the feasibility of an innovative medical 99Mo/99mTc production route using a low-energy accelerator, we measured the excitation function of the 96Zr(a,n)99Mo reaction in the energy range from 11 to 23 MeV using a 24 MeV beam. The present results showed higher values than past data in the peak region, although both data were almost identical above 17 MeV. The production rate of 99Mo from a 96Zr target with incident energies of a particles below 23 MeV was also estimated using the measured excitation function.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/s10967-018-6118-4","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://link.springer.com/article/10.1007%2Fs10967-018-6118-4","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0236-5731","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"萩原, 雅之"}],"nameIdentifiers":[{"nameIdentifier":"804127","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"八島, 浩"}],"nameIdentifiers":[{"nameIdentifier":"804128","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐波, 俊哉"}],"nameIdentifiers":[{"nameIdentifier":"804129","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米内, 俊祐"}],"nameIdentifiers":[{"nameIdentifier":"804130","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hagiwara, Masayuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"804131","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yashima, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"804132","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sanami, Toshiya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"804133","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonai, Shunsuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"804134","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Measurement of the excitation function of 96Zr(α,n)99Mo for an alternative production source of medical radioisotopes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Measurement of the excitation function of 96Zr(α,n)99Mo for an alternative production source of medical radioisotopes"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-08-20"},"publish_date":"2018-08-20","publish_status":"0","recid":"49190","relation_version_is_last":true,"title":["Measurement of the excitation function of 96Zr(α,n)99Mo for an alternative production source of medical radioisotopes"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:41:47.215079+00:00"}