{"created":"2023-05-15T14:38:05.605920+00:00","id":49147,"links":{},"metadata":{"_buckets":{"deposit":"b66a7c54-f47b-4ac2-ae18-5db9417d2243"},"_deposit":{"created_by":1,"id":"49147","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49147"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049147","sets":["1"]},"author_link":["495860","495862","495863","495864","495858","495861","495859","495865"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"10E104-5","bibliographicPageStart":"10E104-1","bibliographicVolumeNumber":"89","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"JT-60SAでの放射計測を目的として抵抗性ボロメータシステム視野設計を行った。特にこれまでの研究で開発した総放射パワー解析用の改良型視野設計手法であるマルチアパチャーボロメータ等を視野設計に適用することで少数のボロメータチャンネルで広範囲のプラズマに関して総放射パワー解析を行うことができる視野を得た。設計した視野ではプラズマ全体を5つのボロメータチャンネルのみで網羅することに成功した。これにより別のポロイダル断面に同じボロメータシステムをつける、同じ視野を持つボロメータシステムを隣接して2台設置するなどの実験中のボロメータ破損に対する冗長性の確保が容易になる。設計した視野についてシミュレーションコードより得られた放射ファントムを用いて設計した視野で得られるSN比を評価した結果、計測に十分なSN比が得られることを確認した。また、設計した視野を用いた総放射パワー解析テストを放射ファントムに対して行った結果、5.7パーセントの誤差で総放射パワーを求めることができることを確認した。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The American Institute of Physics"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5035363","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.1063/1.5035363"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.5035363","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐野, 竜一"}],"nameIdentifiers":[{"nameIdentifier":"495858","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福本, 正勝"}],"nameIdentifiers":[{"nameIdentifier":"495859","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野, 友英"}],"nameIdentifiers":[{"nameIdentifier":"495860","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大山, 直幸"}],"nameIdentifiers":[{"nameIdentifier":"495861","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐野 竜一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495862","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福本 正勝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495863","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野 友英","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495864","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大山 直幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495865","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Conceptual design for resistive bolometer system with multiple apertures for measurement of total radiated power in JT-60SA","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Conceptual design for resistive bolometer system with multiple apertures for measurement of total radiated power in JT-60SA"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-08-24"},"publish_date":"2018-08-24","publish_status":"0","recid":"49147","relation_version_is_last":true,"title":["Conceptual design for resistive bolometer system with multiple apertures for measurement of total radiated power in JT-60SA"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:20:58.841219+00:00"}