{"created":"2023-05-15T14:38:05.117597+00:00","id":49136,"links":{},"metadata":{"_buckets":{"deposit":"021dfdf9-1def-458a-a8c6-3c088763795e"},"_deposit":{"created_by":1,"id":"49136","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49136"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049136","sets":["1"]},"author_link":["495727","495733","495734","495728","495732","495730","495731","495729"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"083501-6","bibliographicPageStart":"083501-1","bibliographicVolumeNumber":"89","bibliographic_titles":[{"bibliographic_title":"Review of scientific instruments"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"総放射パワー解析に適したボロメータシステムを設計するための視野設計手法を開発した。総放射パワー解析誤差を最小化するような最適なボロメータシステム設置位置をトーラス型磁場閉じ込め装置の幾何特性を考慮して求め、その定式化を行った。また、総放射パワー解析に特化したボロメータシステムとして、ボロメータ1つに対してアパチャーを複数用いるマルチアパチャーボロメータシステムを提案し、1台のボロメータで広角の視野を実現した。これらの手法を仮想的なプラズマ閉じ込め装置での総放射パワー解析に適用した結果、1台のボロメータで広範囲の総放射パワーを3パーセント以下の誤差で求めることに成功した。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"American Institute Of Physics"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5026927 ","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.1063/1.5026927"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.5026927","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐野, 竜一"}],"nameIdentifiers":[{"nameIdentifier":"495727","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福本, 正勝"}],"nameIdentifiers":[{"nameIdentifier":"495728","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野, 友英"}],"nameIdentifiers":[{"nameIdentifier":"495729","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大山, 直幸"}],"nameIdentifiers":[{"nameIdentifier":"495730","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐野 竜一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495731","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福本 正勝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495732","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野 友英","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495733","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大山 直幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"495734","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"New design techniques of resistive bolometer system for analysis of total radiated power","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"New design techniques of resistive bolometer system for analysis of total radiated power"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-08-10"},"publish_date":"2018-08-10","publish_status":"0","recid":"49136","relation_version_is_last":true,"title":["New design techniques of resistive bolometer system for analysis of total radiated power"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:21:01.054001+00:00"}