{"created":"2023-05-15T14:37:53.030890+00:00","id":48884,"links":{},"metadata":{"_buckets":{"deposit":"74217092-f5cd-4514-83f7-4b29ff832d5b"},"_deposit":{"created_by":1,"id":"48884","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48884"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048884","sets":["1"]},"author_link":["492477","492481","492471","492472","492469","492466","492468","492465","492467","492475","492480","492464","492473","492470","492474","492476","492478","492479"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-05","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"267","bibliographicPageStart":"261","bibliographicVolumeNumber":"71","bibliographic_titles":[{"bibliographic_title":"Fusion Science and Technology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The approximate estimation of tritium permeation rate under the acceptable assumption from a safety point of view is surely useful to progress the design activities for a fusion DEMO reactor. Tritium permeation rates in the blanket and the divertor were estimated by the simplified evaluation model under the recent DEMO conditions in the water-cooled blanket with solid breeder as a first step. Plasma driven permeation rates in tungsten wall were calculated by applying Doyle & Brice model and gas driven permeation rates in F82H were calculated for hydrogen-tritium two component system. In the representative recent DEMO condition, the following tritium permeation rates were obtained, 1.8 g/day in the blanket first wall, 2.3 g/day in the blanket tritium breeding region and 1.6 g/day in the divertor. Total tritium permeation rate into the cooling water was estimated to be 5.7 g/day.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1080/15361055.2017.1288423","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"片山, 一成"}],"nameIdentifiers":[{"nameIdentifier":"492464","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"染谷, 洋二"}],"nameIdentifiers":[{"nameIdentifier":"492465","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"飛田, 健次"}],"nameIdentifiers":[{"nameIdentifier":"492466","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村, 博文"}],"nameIdentifiers":[{"nameIdentifier":"492467","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷川, 尚"}],"nameIdentifiers":[{"nameIdentifier":"492468","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村, 誠"}],"nameIdentifiers":[{"nameIdentifier":"492469","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"朝倉, 伸幸"}],"nameIdentifiers":[{"nameIdentifier":"492470","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"星野, 一生"}],"nameIdentifiers":[{"nameIdentifier":"492471","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"近田, 拓未"}],"nameIdentifiers":[{"nameIdentifier":"492472","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"波多野, 雄治"}],"nameIdentifiers":[{"nameIdentifier":"492473","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"深田, 智"}],"nameIdentifiers":[{"nameIdentifier":"492474","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"染谷 洋二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492475","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"飛田 健次","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492476","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村 博文","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492477","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷川 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492478","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村 誠","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492479","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"朝倉 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492480","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"星野 一生","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"492481","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Estimation of Tritium Permeation Rate to Cooling Water in Fusion DEMO Condition","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Estimation of Tritium Permeation Rate to Cooling Water in Fusion DEMO Condition"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-05-08"},"publish_date":"2018-05-08","publish_status":"0","recid":"48884","relation_version_is_last":true,"title":["Estimation of Tritium Permeation Rate to Cooling Water in Fusion DEMO Condition"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:23:16.603344+00:00"}