{"created":"2023-05-15T14:37:44.920715+00:00","id":48699,"links":{},"metadata":{"_buckets":{"deposit":"6b21bf58-6e53-4646-aad1-20c90cc23747"},"_deposit":{"created_by":1,"id":"48699","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48699"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048699","sets":["1"]},"author_link":["490005","490007","490004","490006"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"84","bibliographicPageStart":"79","bibliographicVolumeNumber":"90","bibliographic_titles":[{"bibliographic_title":"Physics Procedia"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A several hundred keV class compact proton microbeam system was developed as a prototype of a 1 MeV compact microbeam system to be used in micro-fabrication and micro-analyses. Optimization of an extraction condition was performed to increase demagnification and to achieve a beam diameter of approximately 1 μm. The beam diameter measurement showed that a diameter of 1.8 μm was obtained. This indicates that the compact microbeam system is a feasible alternative to a MeV class conventional large accelerator system.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.phpro.2017.09.022","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.sciencedirect.com/science/article/pii/S1875389217301815?via%3Dihub"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.sciencedirect.com/science/article/pii/S1875389217301815?via%3Dihub","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1875-3892","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大久保, 猛"}],"nameIdentifiers":[{"nameIdentifier":"490004","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石井, 保行"}],"nameIdentifiers":[{"nameIdentifier":"490005","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大久保 猛","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"490006","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石井 保行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"490007","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-04-12"},"publish_date":"2018-04-12","publish_status":"0","recid":"48699","relation_version_is_last":true,"title":["Beam diameter reduction by optimization of an extraction condition in a compact ion microbeam system"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:25:17.555259+00:00"}