{"created":"2023-05-15T14:37:23.897191+00:00","id":48229,"links":{},"metadata":{"_buckets":{"deposit":"07f5afa8-f0e4-49b3-a0c2-d9f9a6a02cf4"},"_deposit":{"created_by":1,"id":"48229","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48229"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048229","sets":["1"]},"author_link":["484570","484574","484583","484579","484566","484573","484581","484576","484582","484571","484578","484577","484567","484569","484580","484568","484575","484572"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"952","bibliographicPageStart":"948","bibliographicVolumeNumber":"69","bibliographic_titles":[{"bibliographic_title":"Journal of the Korean Physical Society"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Control of the beam position for three-dimensional pencil-beam scanning is important because the position accuracy of the beam significantly impacts the alignment of the irradiation field. To\nsuppress this effect, we have developed a simple procedure for beamline tuning. At first, beamline tuning is performed with steering magnets and fluorescent screen monitors to converge the beam's\ntrajectory to a central orbit. Misalignment between the beam’s position and the reference axis is checked by using the verification system, which consists of a screen monitor and an acrylic phantom.\nIf the beam position deviates from the reference axis, two pairs of steering magnets, which are placed on downstream of the beam transport line, will be corrected. These adjustments are iterated\nuntil the deviations for eleven energies of the beam are within 0.5 mm of the reference axis. To demonstrate the success of our procedure, we used our procedure to perform beam commissioning at the Kanagawa Cancer Center.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3938/jkps.69.948","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://link.springer.com/article/10.3938/jkps.69.948"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://link.springer.com/article/10.3938/jkps.69.948","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0374-4884","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"皿谷, 有一"}],"nameIdentifiers":[{"nameIdentifier":"484566","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹下, 英里"}],"nameIdentifiers":[{"nameIdentifier":"484567","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川, 卓司"}],"nameIdentifiers":[{"nameIdentifier":"484568","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原, 洋介"}],"nameIdentifiers":[{"nameIdentifier":"484569","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島, 康太"}],"nameIdentifiers":[{"nameIdentifier":"484570","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早乙女, 直也"}],"nameIdentifiers":[{"nameIdentifier":"484571","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"丹正, 亮平"}],"nameIdentifiers":[{"nameIdentifier":"484572","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井, 敏之"}],"nameIdentifiers":[{"nameIdentifier":"484573","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 耕司"}],"nameIdentifiers":[{"nameIdentifier":"484574","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"皿谷 有一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484575","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹下 英里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484576","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484577","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原 洋介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484578","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島 康太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484579","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早乙女 直也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484580","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"丹正 亮平","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484581","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484582","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484583","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Adjustment Procedure for Beam Alignment in Scanned Ion-Beam Therapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Adjustment Procedure for Beam Alignment in Scanned Ion-Beam Therapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-27"},"publish_date":"2017-07-27","publish_status":"0","recid":"48229","relation_version_is_last":true,"title":["Adjustment Procedure for Beam Alignment in Scanned Ion-Beam Therapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:30:28.154111+00:00"}