{"created":"2023-05-15T14:37:14.395579+00:00","id":48011,"links":{},"metadata":{"_buckets":{"deposit":"3aae3911-7034-4a1b-9f01-f7bf49dc6a26"},"_deposit":{"created_by":1,"id":"48011","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48011"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048011","sets":["1"]},"author_link":["481932","481929","481931","481935","481934","481933","481937","481936","481930","481928"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-04","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"409","bibliographicPageStart":"405","bibliographicVolumeNumber":"169","bibliographic_titles":[{"bibliographic_title":"Springer Proceedings in Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"軟X線レーザーによるアブレーション機構を明らかにすることを目的として、アブレーションによって発生するプラズマ発光の観察を試みた。しかし、アブレーションによる損傷構造が出現するにも関わらずプラズマ発光を捉えることはできなかった。この結果は、軟X線レーザーによるアブレーションでは高温のプラズマが発生しないことを示唆している。実験結果は、シミュレーションから予想される計算結果と矛盾しないことがわかった。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/978-3-319-19521-6_53","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石野, 雅彦"}],"nameIdentifiers":[{"nameIdentifier":"481928","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦野, 将元"}],"nameIdentifiers":[{"nameIdentifier":"481929","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川, 登"}],"nameIdentifiers":[{"nameIdentifier":"481930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山極, 満"}],"nameIdentifiers":[{"nameIdentifier":"481931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河内, 哲哉"}],"nameIdentifiers":[{"nameIdentifier":"481932","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石野 雅彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"481933","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦野 将元","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"481934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川 登","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"481935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山極 満","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"481936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河内 哲哉","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"481937","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Study of optical emission during spallative ablation induced by soft x-ray laser pulses","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Study of optical emission during spallative ablation induced by soft x-ray laser pulses"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-06-05"},"publish_date":"2017-06-05","publish_status":"0","recid":"48011","relation_version_is_last":true,"title":["Study of optical emission during spallative ablation induced by soft x-ray laser pulses"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:33:01.440684+00:00"}