{"created":"2023-05-15T14:37:13.009200+00:00","id":47979,"links":{},"metadata":{"_buckets":{"deposit":"de6a6639-4136-4711-8030-a26428923bb9"},"_deposit":{"created_by":1,"id":"47979","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47979"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047979","sets":["1"]},"author_link":["481635","481634","481637","481633","481631","481636","481630","481638","481632"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"040034-4","bibliographicPageStart":"040034-1","bibliographicVolumeNumber":"1741","bibliographic_titles":[{"bibliographic_title":"AIP Conference Proceedings"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for time-resolved X-ray scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100× 200 μm2) with a pixel pitch of 150 μm and a depletion depth of 10 μm. The multichannel scaler counted X-ray pulses over continuous 2046 time bins for every 0.5 ns and recorded a time spectrum at each pixel with a time resolution of 0.5 ns (FWHM) for 8.0 keV X-rays. Using the detector system, we were able to to observe X-ray peaks clearly separated with 2 ns interval in the multibunch-mode operation of the Photon Factory ring. The small-angle X-ray scattering for polyvinylidene fluoride film was also observed with the detector.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.4952906","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://http://aip.scitation.org/doi/abs/10.1063/1.4952906"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://http://aip.scitation.org/doi/abs/10.1063/1.4952906","subitem_relation_type_select":"URI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岸本, 俊二"}],"nameIdentifiers":[{"nameIdentifier":"481630","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井, 隆也"}],"nameIdentifiers":[{"nameIdentifier":"481631","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"春木, 理恵"}],"nameIdentifiers":[{"nameIdentifier":"481632","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"依田, 芳卓"}],"nameIdentifiers":[{"nameIdentifier":"481633","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"島崎, 昇一"}],"nameIdentifiers":[{"nameIdentifier":"481634","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"斉藤, 正俊"}],"nameIdentifiers":[{"nameIdentifier":"481635","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池野, 正弘"}],"nameIdentifiers":[{"nameIdentifier":"481636","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中, 真伸"}],"nameIdentifiers":[{"nameIdentifier":"481637","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井 隆也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"481638","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Si-APD linear-array x-ray detector with 10-100 μm spatial and sub-nanosecond time resolution","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Si-APD linear-array x-ray detector with 10-100 μm spatial and sub-nanosecond time resolution"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-23"},"publish_date":"2017-05-23","publish_status":"0","recid":"47979","relation_version_is_last":true,"title":["Si-APD linear-array x-ray detector with 10-100 μm spatial and sub-nanosecond time resolution"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:33:24.423737+00:00"}