@article{oai:repo.qst.go.jp:00047896, author = {佐藤, 聡 and 権, セロム and 太田, 雅之 and 落合, 謙太郎 and 今野, 力 and 佐藤 聡 and 権 セロム and 太田 雅之 and 落合 謙太郎}, journal = {Fusion Eng. Design}, month = {Nov}, note = {In order to validate a new library of dosimetry cross section data, International Reactor Dosimetry and Fusion File release 1.0 (IRDFF 1.0), not only for DT neutrons but also for neutrons with energy of less than 14 MeV, we perform an integral test with a Li2O rectangular assembly of 60.7 cm in thickness and a DT neutron source at JAEA/FNS. We place a lot of activation foils at depths of 10.1 cm and 30.4 cm for measurements of dosimetry reaction rates in small space along the central axis in the assembly, measure decay gamma-rays from the activation foils with high-purity Ge detectors after the DT neutron irradiation by the foil activation technique, and deduce a variety of dosimetry reaction rates. We calculate the reaction rates by using a Monte Carlo code MCNP5-1.40 and the nuclear data library ENDF/B-VII.1 with the IRDFF-v.1.05 as the response functions for the dosimetry reactions. The calculation results generally show good agreements with the measured ones, and it can be confirmed that most of the data in the IRDFF-v.1.05 are valid in the neutron field in the Li2O assembly with the DT neutrons.}, pages = {1728--1732}, title = {Integral test of International Reactor Dosimetry and Fusion File with Li2O assembly and DT neutron source at JAEA/FNS}, volume = {109/111}, year = {2016} }