{"created":"2023-05-15T14:37:05.749478+00:00","id":47812,"links":{},"metadata":{"_buckets":{"deposit":"fa11e7b0-a7f9-4913-a05f-dfa256a621c3"},"_deposit":{"created_by":1,"id":"47812","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47812"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047812","sets":["1"]},"author_link":["479950","479948","479951","479954","479953","479956","479952","479949","479955"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1062","bibliographicPageEnd":"20150988-8","bibliographicPageStart":"20150988-1","bibliographicVolumeNumber":"89","bibliographic_titles":[{"bibliographic_title":"The British journal of radiology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"One approach to improving image quality of CT is to use metal artefact reduction image processing, such as single-energy metal artefact reduction (SEMAR). To quantify the impact of image correction on the quality of carbon-ion dose distribution, treatment planning using SEMAR was evaluated.","subitem_description_type":"Abstract"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"26942839","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1259/bjr.20150988","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0007-1285","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Miki, Kentaro"}],"nameIdentifiers":[{"nameIdentifier":"479948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mori, Shinichiro"}],"nameIdentifiers":[{"nameIdentifier":"479949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hasegawa, Azusa"}],"nameIdentifiers":[{"nameIdentifier":"479950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Naganawa, Kensuke"}],"nameIdentifiers":[{"nameIdentifier":"479951","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koto, Masashi"}],"nameIdentifiers":[{"nameIdentifier":"479952","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 慎一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"479953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川 安都佐","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"479954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長縄 憲亮","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"479955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小藤 昌志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"479956","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning."}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-26"},"publish_date":"2017-04-26","publish_status":"0","recid":"47812","relation_version_is_last":true,"title":["Single-energy metal artefact reduction with CT for carbon-ion radiation therapy treatment planning."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:35:16.484720+00:00"}