@article{oai:repo.qst.go.jp:00047770, author = {佐野, 竜一 and Peterson, Byron and Teranishi, Masaru and Iwama, Naofumi and Kobayashi, Masahiro and Mukai, Kiyofumi and 佐野 竜一}, issue = {11}, journal = {REVIEW OF SCIENTIFIC INSTRUMENTS}, month = {Nov}, note = {In tomographic imaging of magnetically confined toroidal plasmas, a countermeasure against missing observation has been studied in terms of the adoption of prior information based on modelled plasma profiles. The Tikhonov regularization for image reconstruction is extended by the use of the Euclidean distance. A procedure of model fitting is designed in order to adaptively generate the reference image. The new method is tested on a typical example of ill-conditioned tomography, that is, the three-dimensional imaging-bolometer tomography in the large helical device. It has been found that the new method is useful for diminishing artifacts and thus for better recognizing the radiation structure of plasma.}, pages = {11D440-1--11D440-4}, title = {Using a priori knowledge for developing bolometric tomography in toroidal devices}, volume = {87}, year = {2016} }