{"created":"2023-05-15T14:36:56.937569+00:00","id":47613,"links":{},"metadata":{"_buckets":{"deposit":"23cf5966-8951-4cae-a839-e9bf6bae5f76"},"_deposit":{"created_by":1,"id":"47613","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47613"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047613","sets":["1"]},"author_link":["773927","773931","773926","773929","773930","773924","773928","773923","773925"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"19","bibliographicPageEnd":"4816","bibliographicPageStart":"4807","bibliographicVolumeNumber":"51","bibliographic_titles":[{"bibliographic_title":"Physics in Medicine and Biology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a simple collimator model to improve the accuracy of penumbra behaviour in pencil-beam dose calculation for proton radiotherapy. In this model, transmission of particles through a three-dimensionally extended opening of a collimator is calculated in conjunction with phase-space distribution of the particles. Comparison of the dose distributions calculated using the new three-dimensional collimator model and the conventional twodimensional model to lateral dose profiles experimentally measured with collimated proton beams showed the superiority of the new model over the conventional one.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"16985272","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1088/0031-9155/51/19/006","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/0031-9155/51/19/006","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0031-9155","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"773923","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akagi, Takashi"}],"nameIdentifiers":[{"nameIdentifier":"773924","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takatani, Yasuyuki"}],"nameIdentifiers":[{"nameIdentifier":"773925","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonai, Shunsuke"}],"nameIdentifiers":[{"nameIdentifier":"773926","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sakamoto, Hidenobu"}],"nameIdentifiers":[{"nameIdentifier":"773927","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamashita, Haruo"}],"nameIdentifiers":[{"nameIdentifier":"773928","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"773929","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akagi, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"773930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonai, Shunsuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"773931","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-06"}],"displaytype":"detail","filename":"60f4b8f8ebf7421d3f7d02fd326c46e0.pdf","filesize":[{"value":"386.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"manuscript.pdf","url":"https://repo.qst.go.jp/record/47613/files/60f4b8f8ebf7421d3f7d02fd326c46e0.pdf"},"version_id":"14372883-f06f-44c4-9b73-1d5106e87fec"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Extended collimator model for pencil-beam dose calculation in proton radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Extended collimator model for pencil-beam dose calculation in proton radiotherapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-09-08"},"publish_date":"2006-09-08","publish_status":"0","recid":"47613","relation_version_is_last":true,"title":["Extended collimator model for pencil-beam dose calculation in proton radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:24:46.364512+00:00"}