@article{oai:repo.qst.go.jp:00047610, author = {Lang, K. and Ambrose, D. and Arroyo, C. and Bachman, M. and Connor, D. and Eckhause, M. and M., Ecklund K. and Graessie, S. and Hamela, M. and Hamilton, S. and D., Hancock A. and Hartman, K. and Hebert, M. and H., Hoff C. and W., Hoffmann G. and M., Irwin G. and R., Kane J. and Kanematsu, Nobuyuki and Kuang, Y. and Lee, R. and Marcin, M. and D., Martin R. and McDonough, J. and Milder, A. and R., Molzon W. and Ouimette, D. and Pommot-Maia, M. and Proga, M. and J., Riley P. and L., Ritchie J. and D., Rubin P. and I., Vassilakopoulos V. and Ware, B. and E., Welsh R. and G., Wojcicki S. and S., Worm and 兼松 伸幸}, issue = {3}, journal = {Nuclear Instruments & Methods in Physics Research Section A}, month = {Apr}, note = {We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5-mm-diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and redundant particle identification to remove backgrounds.}, pages = {274--293}, title = {A straw drift chamber spectrometer for studies of rare kaon decays}, volume = {522}, year = {2004} }