@article{oai:repo.qst.go.jp:00047608, author = {Tan, Yanliang and Ishikawa, Tetsuo and ミロソラフ, ヤニック and Tokonami, Shinji and Hosoda, Masahiro and Sorimachi, Atsuyuki and Kearfott, Kimberlee and ミロソラフ ヤニック}, issue = {1}, journal = {Science of the Total Environment}, month = {Dec}, note = {The accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in Japan resulted in significant releases of fission products. While substantial data exist concerning outdoor air radioactivity following the accident, the resulting indoor radioactivity remains pure speculation without a proper method for estimating the ratio of the indoor to outdoor airborne radioactivity, termed the airborne sheltering factor (ASF). Lacking a meaningful value of the ASF, it is difficult to assess the inhalation doses to residents and evacuees even when outdoor radionuclide concentrations are available. A simple model was developed and the key parameters needed to estimate the ASF were obtained through data fitting of selected indoor and outdoor airborne radioactivity measurement data obtained following the accident at a single location. Using the new model with values of the air exchange rate, interior air volume, and the inner surface area of the dwellings, the ASF can be estimated for a variety of dwelling types. Assessment of the inhalation dose to individuals readily follows from the value of the ASF, the person's indoor occupancy factor, and the measured outdoor radioactivity concentration.}, pages = {25--30}, title = {Novel method for estimation of the indoor-to-outdoor airborne radioactivity ratio following the Fukushima Daiichi Nuclear Power Plant accident}, volume = {536}, year = {2015} }