{"created":"2023-05-15T14:36:55.542932+00:00","id":47581,"links":{},"metadata":{"_buckets":{"deposit":"302c7641-5206-43d2-b293-677cb8ad3d6b"},"_deposit":{"created_by":1,"id":"47581","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47581"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047581","sets":["1"]},"author_link":["476913","476918","476917","476915","476916","476914"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"1020","bibliographicPageStart":"1016","bibliographicVolumeNumber":"39","bibliographic_titles":[{"bibliographic_title":"Medical Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose: In treatment planning of charged-particle radiotherapy, patient heterogeneity is conventionally modeled as variable-density water converted from CT images to best reproduce the stopping power, which may lead to inaccuracies in the handling of multiple scattering and nuclear interactions. Although similar conversions can be defined for these individual interactions, they would be valid only for specific CT systems and would require additional tasks for clinical application. This study aims to improve the practicality of the interaction-specific heterogeneity correction.\nMethods: The authors calculated the electron densities and effective densities for stopping power, multiple scattering, and nuclear interactions of protons and ions, using the standard elemental-composition data for body tissues to construct the invariant conversion functions. The authors also simulated a proton beam in a lung-like geometry and a carbon-ion beam in a prostate-like geometry to demonstrate the procedure and the effects of the interaction-specific heterogeneity correction.\nResults: Strong correlations were observed between the electron density and the respective effective densities, with which the authors formulated polyline conversion functions. Their effects amounted to 10% differences in multiple-scattering angle and nuclear interaction mean free path for bones compared to those in the conventional heterogeneity correction. Although their realistic effect on patient dose distributions would be generally small, it could be at the level of a few percent when a carbon-ion beam traverses a large bone.\nConclusions: The present conversion functions are invariant and may be incorporated in treatment planning systems with a common function relating CT number to electron density. This will enable improved beam dose calculation while minimizing initial setup and quality management of the user's specific system.","subitem_description_type":"Abstract"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"22320811","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1118/1.3679339","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0094-2405","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"476913","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Inaniwa, Taku"}],"nameIdentifiers":[{"nameIdentifier":"476914","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koba, Yusuke"}],"nameIdentifiers":[{"nameIdentifier":"476915","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"兼松 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476916","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲庭 拓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476917","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場 裕介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476918","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-14"}],"displaytype":"detail","filename":"67c4796a33209b785460ae6909ca3891.pdf","filesize":[{"value":"152.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"manuscript.pdf","url":"https://repo.qst.go.jp/record/47581/files/67c4796a33209b785460ae6909ca3891.pdf"},"version_id":"a2abe0b2-6aa3-4b75-ade3-739c4e4ee1f7"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interactions of proton and ion beams","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interactions of proton and ion beams"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-10-18"},"publish_date":"2016-10-18","publish_status":"0","recid":"47581","relation_version_is_last":true,"title":["Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interactions of proton and ion beams"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:38:02.609937+00:00"}