{"created":"2023-05-15T14:36:55.277108+00:00","id":47575,"links":{},"metadata":{"_buckets":{"deposit":"1e4f6d01-a5cc-4110-af09-3d8190ca2f19"},"_deposit":{"created_by":1,"id":"47575","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47575"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047575","sets":["1"]},"author_link":["476890","476891","476894","476896","476889","476892","476893","476895"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"12","bibliographicPageEnd":"3127","bibliographicPageStart":"3113","bibliographicVolumeNumber":"53","bibliographic_titles":[{"bibliographic_title":"Physics in Medicine and Biology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A model for beam customization with collimators and a range-compensating filter based on the phase-space theory for beam transport is presented for dose distribution calculation in treatment planning of radiotherapy with protons and heavier ions. Independent handling of pencil beams in conventional pencil-beam algorithms causes unphysical collimator-height dependence in the middle of large fields, which is resolved by the framework comprised of generation, transport, collimation, regeneration, range-compensation, and edge-sharpening processes with a matrix of pencil beams. The model was verified to be consistent with measurement and analytic estimation at a submillimeter level in penumbra of individual collimators with a combinational-collimated carbon-ion beam. The model computation is fast, accurate, and readily applicable to pencil-beam algorithms in treatment planning with capability of combinational collimation to make best use of the beam-customization devices.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"18495975","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1088/0031-9155/53/12/003","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0031-9155","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"476889","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonai, Shunsuke"}],"nameIdentifiers":[{"nameIdentifier":"476890","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishizaki, Azusa"}],"nameIdentifiers":[{"nameIdentifier":"476891","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Torikoshi, Masami"}],"nameIdentifiers":[{"nameIdentifier":"476892","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"兼松 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476893","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米内 俊祐","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476894","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石崎 梓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476895","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"取越 正己","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476896","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-14"}],"displaytype":"detail","filename":"141108ca1e1b346f66289618ba5574e8.pdf","filesize":[{"value":"250.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"paper.pdf","url":"https://repo.qst.go.jp/record/47575/files/141108ca1e1b346f66289618ba5574e8.pdf"},"version_id":"faf6e6c9-b13d-4544-a6d2-f232d68df680"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Computational modeling of beam-customization devices for heavy-charged-particle radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Computational modeling of beam-customization devices for heavy-charged-particle radiotherapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-10-18"},"publish_date":"2016-10-18","publish_status":"0","recid":"47575","relation_version_is_last":true,"title":["Computational modeling of beam-customization devices for heavy-charged-particle radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:38:10.738283+00:00"}