{"created":"2023-05-15T14:36:55.147567+00:00","id":47572,"links":{},"metadata":{"_buckets":{"deposit":"7f3aee70-589e-4129-bf66-b6c068bc5cdb"},"_deposit":{"created_by":1,"id":"47572","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47572"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047572","sets":["1"]},"author_link":["773938","773933","773934","773937","773932","773935","773936"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"N5","bibliographicPageStart":"N1","bibliographicVolumeNumber":"49","bibliographic_titles":[{"bibliographic_title":"Physics in Medicine and Biology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An idea of computer-controlled range-compensating system for heavy charged particle radiotherapy, the multibar compensator, is proposed. \nBy stacking multiple energy-absorbing layers along the beam, each of which has structure and behaviour similar to those of a multileaf collimator, variable range compensation will be achieved. \nThe analysis of the conventional range compensators actually used for treatment concluded that the proposed system would not seriously degrade the treatment quality for the most cases, except for tumours in head and neck region where 1-mm precision may be required.\nThe system will even be able to coexist with the conventional range compensators to provide either method depending on clinical situations.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"15083676","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1088/0031-9155/49/2/N01","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/0031-9155/49/2/N01","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0031-9155","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"773932","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Asaskura, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"773933","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kohno, Ryosuke"}],"nameIdentifiers":[{"nameIdentifier":"773934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, Osamu"}],"nameIdentifiers":[{"nameIdentifier":"773935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"773936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kohno, Ryosuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"773937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, Osamu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"773938","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-06"}],"displaytype":"detail","filename":"8791bd20242879e01fb089375c85e57f.pdf","filesize":[{"value":"113.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"note.pdf","url":"https://repo.qst.go.jp/record/47572/files/8791bd20242879e01fb089375c85e57f.pdf"},"version_id":"e034b801-b0d8-44e9-9f2b-812d0a80db62"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Tumour shapes and fully automated range compensation for heavy charged particle radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Tumour shapes and fully automated range compensation for heavy charged particle radiotherapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-11-18"},"publish_date":"2003-11-18","publish_status":"0","recid":"47572","relation_version_is_last":true,"title":["Tumour shapes and fully automated range compensation for heavy charged particle radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:24:40.905430+00:00"}