{"created":"2023-05-15T14:36:46.082227+00:00","id":47370,"links":{},"metadata":{"_buckets":{"deposit":"9acab690-f130-4e51-9c8e-2012cafe0312"},"_deposit":{"created_by":1,"id":"47370","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47370"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047370","sets":["1"]},"author_link":["474148","474154","474147","474153","474152","474151","474149","474150","474155"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-3","bibliographicPageEnd":"159","bibliographicPageStart":"155","bibliographicVolumeNumber":"167","bibliographic_titles":[{"bibliographic_title":"Radiation Protection Dosimetry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The present study focuses on internal exposure caused by the inhalation of radon and thoron progenies because the internal exposures have not yet been clarified. For their dose assessment, radon, thoron and thoron progeny concentrations were measured by passive monitors over a long period (for 6 months). Consequently, radon, thoron and equilibrium equivalent thoron concen- trations were given as 124 + 78, 1247 + 1189 and 7.8 + 9.1 Bq m23, respectively. Annual effective doses are estimated to be 3.1 + 2.0 mSv for radon and 2.2 + 2.5 mSv for thoron. Total dose are estimated to be 5.3 + 3.5 mSv a21. The present study has revealed that the radon dose was comparable with the thoron dose, and the total dose was ∼2 times higher than the worldwide average.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Oxford University Press"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0144-8420","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"H.Kudo"}],"nameIdentifiers":[{"nameIdentifier":"474147","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tokonami, S."}],"nameIdentifiers":[{"nameIdentifier":"474148","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Omori, Y."}],"nameIdentifiers":[{"nameIdentifier":"474149","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishikawa, T."}],"nameIdentifiers":[{"nameIdentifier":"474150","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwaoka, K."}],"nameIdentifiers":[{"nameIdentifier":"474151","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sahoo, S.K."}],"nameIdentifiers":[{"nameIdentifier":"474152","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akata, N."}],"nameIdentifiers":[{"nameIdentifier":"474153","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"M.Hosoda"}],"nameIdentifiers":[{"nameIdentifier":"474154","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"サフー サラタ クマール","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"474155","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"COMPARATIVE DOSIMETRY FOR RADON AND THORON IN HIGH BACKGROUND RADIATION AREAS IN CHINA","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"COMPARATIVE DOSIMETRY FOR RADON AND THORON IN HIGH BACKGROUND RADIATION AREAS IN CHINA"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-01-18"},"publish_date":"2016-01-18","publish_status":"0","recid":"47370","relation_version_is_last":true,"title":["COMPARATIVE DOSIMETRY FOR RADON AND THORON IN HIGH BACKGROUND RADIATION AREAS IN CHINA"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:40:39.691311+00:00"}