{"created":"2023-05-15T14:36:42.097460+00:00","id":47280,"links":{},"metadata":{"_buckets":{"deposit":"62c9b933-5416-4af7-a4b5-b373eacc417b"},"_deposit":{"created_by":1,"id":"47280","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47280"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047280","sets":["1"]},"author_link":["472894","472888","472893","472885","472886","472896","472890","472891","472892","472887","472897","472889","472895"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"5515","bibliographicPageStart":"5511","bibliographicVolumeNumber":"87","bibliographic_titles":[{"bibliographic_title":"Analytical Chemistry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An acidic leaching method using HNO3 is widely employed to release the global fallout Pu from soil samples for further chemical separations in radioecology and toxicology studies, and in many applications using Pu as a useful tracer. In the method’s sample ash treatment step to decompose organic matter in soil, various ashing temperatures (400 – 900˚C) are used. However, the effect of ashing temperature on the accurate Pu analysis has not been well investigated. In this study, two standard reference soils (IAEA-soil-6 and IAEA-375) were used to determine the ashing temperature effect (from 375 to 600˚C) on HNO3 leaching method. The Pu analytical results of both standard reference materials showed that lower 239+240Pu activity was observed when the ashing temperature exceeded 450˚C, and the 239+240Pu activity continue to decrease as the ashing temperature was raised. Approximately 40% of the Pu content could not be leached out by concentrate HNO3 after ashing for 4 h at 600˚C. The Pu loss was attributed to the formation of refractory materials, which are insoluble in HNO3 solution. This hypothesis was confirmed by the XRD analysis of soil samples which revealed that plagioclase-like silicate materials were formed after high temperature ashing. To ensure the Pu release efficiency in HNO3 leaching, we recommend 450˚C as the ideal ashing temperature. This recommendation is also useful for analysis of other important artificial radionuclides (e.g. 137Cs, 90Sr, 241Am) for which an ashing process is needed to decompose the organic content in soil samples.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"ACS Publications"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1021/acs.analchem.5b01472","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0003-2700","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"王, 鍾堂"}],"nameIdentifiers":[{"nameIdentifier":"472885","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yang, Guosheng"}],"nameIdentifiers":[{"nameIdentifier":"472886","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鄭, 建"}],"nameIdentifiers":[{"nameIdentifier":"472887","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"曹, 立国"}],"nameIdentifiers":[{"nameIdentifier":"472888","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yu, Haijun"}],"nameIdentifiers":[{"nameIdentifier":"472889","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Zhu, Yanbei"}],"nameIdentifiers":[{"nameIdentifier":"472890","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上, 恵子"}],"nameIdentifiers":[{"nameIdentifier":"472891","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田, 滋夫"}],"nameIdentifiers":[{"nameIdentifier":"472892","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"王 鍾堂","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472893","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鄭 建","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472894","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"曹 立国","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472895","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472896","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"472897","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-14"}],"displaytype":"detail","filename":"ef4654585c75651f378cb7a9e8c84663.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Wang et al-Effect of ashing temperature on soil Pu analysis-Anal Chem2015.pdf","url":"https://repo.qst.go.jp/record/47280/files/ef4654585c75651f378cb7a9e8c84663.pdf"},"version_id":"9d773006-f8a3-4e40-ba5f-e3f298721721"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Effect of ashing temperature on accurate determination of plutonium in soil samples","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Effect of ashing temperature on accurate determination of plutonium in soil samples"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-09-15"},"publish_date":"2015-09-15","publish_status":"0","recid":"47280","relation_version_is_last":true,"title":["Effect of ashing temperature on accurate determination of plutonium in soil samples"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:41:41.001274+00:00"}