{"created":"2023-05-15T14:36:31.703090+00:00","id":47045,"links":{},"metadata":{"_buckets":{"deposit":"741cbb39-3c11-4cdc-92d8-bb5b45361a80"},"_deposit":{"created_by":1,"id":"47045","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47045"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047045","sets":["1"]},"author_link":["469763","469760","469765","469768","469759","469764","469767","469761","469757","469758","469766","469762"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"021706-8","bibliographicPageStart":"021706-1","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"Medical physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It is essential to consider large-angle scattered particles in dose calculation models for therapeutic carbon-ion beams. However, it is difficult to measure the small dose contribution from large-angle scattered particles. In this paper, the authors present a novel method to derive the parameters describing large-angle scattered particles from the measured results.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"24506597","subitem_relation_type_select":"PMID"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0094-2405","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hara, Yousuke"}],"nameIdentifiers":[{"nameIdentifier":"469757","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"469758","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Inaniwa, Taku"}],"nameIdentifiers":[{"nameIdentifier":"469759","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizushima, Kota"}],"nameIdentifiers":[{"nameIdentifier":"469760","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"469761","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Koji"}],"nameIdentifiers":[{"nameIdentifier":"469762","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原 洋介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"469763","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"469764","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲庭 拓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"469765","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島 康太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"469766","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"469767","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"469768","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A novel method for experimental characterization of large-angle scattered particles in scanned carbon-ion therapy.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A novel method for experimental characterization of large-angle scattered particles in scanned carbon-ion therapy."}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-19"},"publish_date":"2015-03-19","publish_status":"0","recid":"47045","relation_version_is_last":true,"title":["A novel method for experimental characterization of large-angle scattered particles in scanned carbon-ion therapy."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:44:33.659413+00:00"}