{"created":"2023-05-15T14:36:09.367216+00:00","id":46542,"links":{},"metadata":{"_buckets":{"deposit":"d1d62842-eda2-466d-8904-449a71c2de4f"},"_deposit":{"created_by":1,"id":"46542","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"46542"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00046542","sets":["1"]},"author_link":["463841","463840","463839","463843","463838","463837","463842"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"28","bibliographicPageStart":"22","bibliographicVolumeNumber":"689","bibliographic_titles":[{"bibliographic_title":"Nuclear Instruments & Methods in Physics Research Section A"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We developed a real-time and non-destructive method of beam profile measurement on a target under large beam current irradiation, and without any complex radiation detectors or electrical circuits. We measured the beam profiles on a target by observing the target temperature using an infrared-radiation thermometer camera. The target temperatures were increased and decreased quickly by starting and stopping the beam irradiation within 1 s in response speed. \n Our method could trace beam movements rapidly. The beam size and positiun were calibrated by measuring O-ring heat on the target. Our method has the potential to measure beam profiles at beam current over 1 mA for proton and deuteron with the energy around 3Mev and allows accelerator operators to adjust the beam location during beam irradiation experiments without decreaseing the beam current.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"org/10.1016/j.nima.2012.06.019","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0168-9002","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Takada, Masashi"}],"nameIdentifiers":[{"nameIdentifier":"463837","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kamada, So"}],"nameIdentifiers":[{"nameIdentifier":"463838","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hamano, Tsuyoshi"}],"nameIdentifiers":[{"nameIdentifier":"463839","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"463840","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高田 真志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463841","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田 創","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463842","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"463843","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-04-30"},"publish_date":"2013-04-30","publish_status":"0","recid":"46542","relation_version_is_last":true,"title":["Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:50:31.902934+00:00"}