ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Cell-penetrating nitroxides as molecular sensors for imaging of cancer in vivo, based on tissue redox activity

https://repo.qst.go.jp/records/46532
https://repo.qst.go.jp/records/46532
766720aa-60b9-4a94-ab1a-0387598a540c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-04-15
タイトル
タイトル Cell-penetrating nitroxides as molecular sensors for imaging of cancer in vivo, based on tissue redox activity
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zhelev, Zhivko

× Zhelev, Zhivko

WEKO 463739

Zhelev, Zhivko

Search repository
Veselina, Gadjeva

× Veselina, Gadjeva

WEKO 463740

Veselina, Gadjeva

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 463741

Aoki, Ichio

Search repository
Bakalova-Zheleva, Rumiana

× Bakalova-Zheleva, Rumiana

WEKO 463742

Bakalova-Zheleva, Rumiana

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 463743

Saga, Tsuneo

Search repository
Zhelev Zhivko

× Zhelev Zhivko

WEKO 463744

en Zhelev Zhivko

Search repository
青木 伊知男

× 青木 伊知男

WEKO 463745

en 青木 伊知男

Search repository
バカロバ ルミアナ

× バカロバ ルミアナ

WEKO 463746

en バカロバ ルミアナ

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 463747

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 The present study shows that hydrophobic and cell-penetrating piperidine-type nitroxide radicals SLENU and TEMPOL, but not hydrophilic and partially penetrating or non-penetrating pyrrolidine-type nitroxides carbamoyl-PROXYL and carboxy-PROXYL, are appropriate contrast agents for magnetic resonance imaging (MRI) of cancer, based on its functionality - tissue redox activity. The experiments were conducted on anesthetized mice: healthy and neuroblastoma-bearing in a moderate stage of cancer development. The method is based on the nitroxide redox cycle, coupled with appearance or disappearance of the MRI signal. The half-life (T1/2) of a nitroxide-enhanced MRI signal in the respective tissue was used as a marker to assess tissue redox activity to the nitroxide radical. In the case of SLENU and TEMPOL, there were large differences in the histograms between control and cancer-bearing mice. All tissues (cancer and non-cancer) of cancer-bearing organisms were characterized by a long-lived MRI signal (T1/2 > 14 min), indicating a high oxidative activity. The tissues of healthy organisms were characterized by a short-lived MRI signal (T1/2 = 1-3 min), indicating a high reducing activity. In the case of carbamoyl-PROXYL and carboxy-PROXYL, there was no difference in the histograms between control and cancer-bearing mice. The data show that the penetration of nitroxide in cells and tissues is obligatory for imaging of cancer, based on its redox activity. The principle of the method is applicable also to biopsy specimens, using MRI or EPR spectroscopy. We provide direct evidence that the nitroxide redox cycle could be used as a sensing platform for functional imaging of different pathologies, based on changes in cellular and tissue redox activity, as in the case of cancer.
書誌情報 Molecular BioSystems

巻 8, 号 10, p. 2733-2740, 発行日 2012-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 1742-206X
DOI
識別子タイプ DOI
関連識別子 10.1039/c2mb25128k
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:50:38.982355
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3