{"created":"2023-05-15T14:35:16.518711+00:00","id":45456,"links":{},"metadata":{"_buckets":{"deposit":"ee95a9bf-203b-46ab-bf75-9cb10fe531be"},"_deposit":{"created_by":1,"id":"45456","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45456"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045456","sets":["1"]},"author_link":["451637","451639","451636","451640","451641","451635","451638","451632","451633","451634"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"3258","bibliographicPageStart":"3252","bibliographicVolumeNumber":"35","bibliographic_titles":[{"bibliographic_title":"Medical Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A multi-slit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an X-ray energy of about 100 keV. It consists of 30 slits that are 25 um high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25um-thick polyimide sheets that were separated by 175um-thick tungsten sheets. We measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a CCD camera and found that the ratios of the dose at the center of a microbeam to that at mid-positions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code Phits.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0094-2405","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ohno, Yumiko"}],"nameIdentifiers":[{"nameIdentifier":"451632","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Torikoshi, Masami"}],"nameIdentifiers":[{"nameIdentifier":"451633","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuki, Masao"}],"nameIdentifiers":[{"nameIdentifier":"451634","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Umetani, Keiji"}],"nameIdentifiers":[{"nameIdentifier":"451635","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uesugi, Kentaro"}],"nameIdentifiers":[{"nameIdentifier":"451636","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yagi, Naoto"}],"nameIdentifiers":[{"nameIdentifier":"451637","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"451638","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野 由美子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"451639","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"取越 正己","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"451640","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 雅雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"451641","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-03-26"},"publish_date":"2009-03-26","publish_status":"0","recid":"45456","relation_version_is_last":true,"title":["Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:03:31.291242+00:00"}