{"created":"2023-05-15T14:35:12.539220+00:00","id":45396,"links":{},"metadata":{"_buckets":{"deposit":"d7d61eaf-4b5e-4b7d-a215-7f3863c9b8bf"},"_deposit":{"created_by":1,"id":"45396","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45396"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045396","sets":["1"]},"author_link":["450964","450961","450960","450962","450959","450965","450963"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"26","bibliographicPageEnd":"261901-3","bibliographicPageStart":"261901-1","bibliographicVolumeNumber":"93","bibliographic_titles":[{"bibliographic_title":"Applied Physics Letters"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a fast x-ray detector using an organic-inorganic perovskite scintillator of phenethylamine lead bromide (PhE-PbBr4). The scintillator had a dominant light emission with a fast decay time of 9.9 ns. An x-ray detector equipped with a 0.9-mm-thick PhE-PbBr4 crystal was used to detect nuclear resonant scattering in 61Ni (the first excited level: 67.41 keV; lifetime: 7.6 ns) by using synchrotron radiation. With this detector, we could successfully record the decaying gamma rays emitted from 61Ni with a time resolution of 0.7 ns (full width at half maximum) and a relatively high detection efficiency of 24%.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.3059562","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0003-6951","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kishimoto, Shunji"}],"nameIdentifiers":[{"nameIdentifier":"450959","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shibuya, Kengo"}],"nameIdentifiers":[{"nameIdentifier":"450960","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishikido, Fumihiko"}],"nameIdentifiers":[{"nameIdentifier":"450961","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koshimizu, Masanori"}],"nameIdentifiers":[{"nameIdentifier":"450962","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"450963","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"澁谷 憲悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450964","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦戸 文彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450965","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Subnanosecond time-resolved x-ray measurements using an organic-inorganic perovskite scintillator","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Subnanosecond time-resolved x-ray measurements using an organic-inorganic perovskite scintillator"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-01-13"},"publish_date":"2009-01-13","publish_status":"0","recid":"45396","relation_version_is_last":true,"title":["Subnanosecond time-resolved x-ray measurements using an organic-inorganic perovskite scintillator"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:04:13.137311+00:00"}