{"created":"2023-05-15T14:35:11.875463+00:00","id":45386,"links":{},"metadata":{"_buckets":{"deposit":"493c6031-9c17-44fb-9398-15ad6e72d66f"},"_deposit":{"created_by":1,"id":"45386","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45386"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045386","sets":["1"]},"author_link":["450857","450859","450852","450854","450856","450855","450853","450858"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9 Issue 1","bibliographicPageEnd":"7327","bibliographicPageStart":"7324","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"Japanese Journal of Applied Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Antioxidant doped CR-39 detectors were loaded onto the STS-95 space shuttle mission (altitude: 574 km; inclination: 28.45 degree; flight duration: 8.9 days) for measuring the linear energy transfer (LET) distribution above 10 keV/um for space radiation dosimetry. It is known that the track formation sensitivity of antioxidant doped CR-39 detectors depends on the dip angle of the incident particle. We investigated this dip angle dependence for a wide range of LET values and dip angles. The track formation sensitivities at lower dip angles were obviously decreased in the LET region below 100 keV/um. We introduced minimum-cutoff dip angles in order to correct for such dip-angle dependence. The LET distribution of the STS-95 mission was obtained from the measurements of etch pits having dip angles larger than the minimum-cutoff dip angles. This new correction method increased the absorbed dose and dose equivalent above 10 keV/um by 54 and 28%, respectively.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0021-4922","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tawara, Hiroko"}],"nameIdentifiers":[{"nameIdentifier":"450852","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masukawa, Mitsuyo"}],"nameIdentifiers":[{"nameIdentifier":"450853","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagamatsu, Aiko"}],"nameIdentifiers":[{"nameIdentifier":"450854","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yasuda, Nakahiro"}],"nameIdentifiers":[{"nameIdentifier":"450855","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"450856","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"俵 裕子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450857","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"益川 充代","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450858","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田 仲宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450859","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Measurement of a Linear Energy Transfer Distribution with Antioxidant Doped CR-39 Correcting for the Dip Angle Dependence of Track Formation Sensitivity","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Measurement of a Linear Energy Transfer Distribution with Antioxidant Doped CR-39 Correcting for the Dip Angle Dependence of Track Formation Sensitivity"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-01-05"},"publish_date":"2009-01-05","publish_status":"0","recid":"45386","relation_version_is_last":true,"title":["Measurement of a Linear Energy Transfer Distribution with Antioxidant Doped CR-39 Correcting for the Dip Angle Dependence of Track Formation Sensitivity"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:04:20.208939+00:00"}