{"created":"2023-05-15T14:35:09.568313+00:00","id":45351,"links":{},"metadata":{"_buckets":{"deposit":"f61dc990-063b-4219-9910-e09c77ef14a4"},"_deposit":{"created_by":1,"id":"45351","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45351"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045351","sets":["1"]},"author_link":["450511","450508","450510","450513","450512","450509"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"814","bibliographicPageStart":"811","bibliographicVolumeNumber":"170","bibliographic_titles":[{"bibliographic_title":"Radiation Research"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A new method for calibration was developed that takes the\nenergy deposited by radioisotope sources into account; it was\nvalidated with a plastic scintillation plate using a 207Bi source.\nThe energy deposits of the conversion electrons in the 207Bi\nsource led to an energy difference of a few keV for the 976\nkeV monoenergetic peak. Calibration with high accuracy is\nessential to estimate radiation doses as well as to evaluate detector\nperformance. The method will be available not only for\nuse in scintillation detectors but also for other detectors.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0033-7587","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakamura, Hidehito"}],"nameIdentifiers":[{"nameIdentifier":"450508","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ejiri, Hiroyasu"}],"nameIdentifiers":[{"nameIdentifier":"450509","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kitamura, Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"450510","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村 秀仁","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450511","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"江尻 宏泰","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450512","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"450513","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-12-18"},"publish_date":"2008-12-18","publish_status":"0","recid":"45351","relation_version_is_last":true,"title":["A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:04:44.915536+00:00"}