@article{oai:repo.qst.go.jp:00045303, author = {Hajek, Michael and Berger, Thomas and Vana, Norbert and Uchihori, Yukio and Yasuda, Nakahiro and Kitamura, Hisashi and et.al and 内堀 幸夫 and 安田 仲宏 and 北村 尚}, issue = {2/6}, journal = {Radiation Measurements}, month = {Jun}, note = {First-order thermoluminescence (TL) kinetics computerized glow curve deconvolution (CGCD) and manual analysis of the composite peak structures have been applied to study the behaviour of glow peaks 3 and 5 in CaF2:Tm (TLD-300, Harshaw-Thermo Fisher Scientific) single crystals after heavy charged particle (HCP) irradiation with respect to 60Co gamma rays for a linear energy transfer (LET) interval from 2.3 to 339.4keVmm-1. The ratio of peak 5 to peak 3 heights can be used to evaluate effective LET and correct measured doses for TL efficiency. The applicability of this idea to dose equivalent estimation in exotic radiation fields of complex composition is discussed critically.}, pages = {1135--1139}, title = {LET dependence of thermoluminescent efficiency and peak height ratio of CaF2:Tm}, volume = {43}, year = {2008} }