{"created":"2023-05-15T14:35:00.792370+00:00","id":45222,"links":{},"metadata":{"_buckets":{"deposit":"944e9932-815a-4fa7-acb8-9855806ede14"},"_deposit":{"created_by":1,"id":"45222","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45222"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045222","sets":["1"]},"author_link":["449160","449164","449163","449168","449166","449167","449169","449159","449165","449162","449161","449170"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"2242","bibliographicPageStart":"2235","bibliographicVolumeNumber":"35","bibliographic_titles":[{"bibliographic_title":"Medical Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The authors have developed a method to reconstruct the 3D dose distribution in a particle beam scanning irradiation system. In this scheme, 3D dose distribution is reconstructed by using the measured images of fluence distribution, which are taken for each iso-energy slice (i.e., the unit of the depth scanning). A fluorescent screen with a CCD camera is used to measure the fluence distribution. This system was installed at the HIMAC experimental port and tested by using carbon ion beams. Since a maximum difference between the reconstructed dose and the ionization chamber measurement was around 5% in the target volume, this system can be useful for quick verification of 3D dose distribution.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1118/1.2911868","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0094-2405","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"449159","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saotome, Naoya"}],"nameIdentifiers":[{"nameIdentifier":"449160","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Inaniwa, Taku"}],"nameIdentifiers":[{"nameIdentifier":"449161","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satou, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"449162","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Kouji"}],"nameIdentifiers":[{"nameIdentifier":"449163","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"449164","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"449165","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早乙女 直也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"449166","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲庭 拓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"449167","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤 眞二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"449168","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"449169","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"449170","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Delivery verification using 3D dose reconstruction based on fluorescence measurement in a carbon beam scanning irradiation system","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Delivery verification using 3D dose reconstruction based on fluorescence measurement in a carbon beam scanning irradiation system"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-07-14"},"publish_date":"2008-07-14","publish_status":"0","recid":"45222","relation_version_is_last":true,"title":["Delivery verification using 3D dose reconstruction based on fluorescence measurement in a carbon beam scanning irradiation system"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:06:17.695211+00:00"}