{"created":"2023-05-15T14:34:38.996912+00:00","id":44779,"links":{},"metadata":{"_buckets":{"deposit":"e796e400-f438-4079-9dfb-d19474170f2b"},"_deposit":{"created_by":1,"id":"44779","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44779"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044779","sets":["1"]},"author_link":["444615","444614","444613","444612","444616"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"27","bibliographicPageStart":"17","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"医用標準線量"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"光子の線量を評価する場合、相互作用係数が重要となる。とりわけ、質量エネル\nギー吸収係数と質量エネルギー転移係数が必要となる。前者は吸収線量の評価で\n必要となり、後者はカーマの算定で必要である。空気カーマは吸収線線量測定の\n電離箱の校正で必要となる。両者は同じ単位系で定義され、特別名称もGyであ\nる。一般に水の吸収線量が生物・医学系では基準になるが、水の吸収線量と水の\n衝突カーマはエネルギー付与の観点からは等しくなる筈であるが、両者は必ずし\nも等しくならない。それは、カーマはエネルギー転移が点で決まるのに対して、\n吸収線量は二次荷電粒子の飛程にわたるエネルギー付与を考える必要があるから\nである。しかしここではカーマと吸収線量におけるエネルギー付与の関係につい\nては論じない。\n\\n光子の相互作用係数である、質量エネルギー吸収係数と質量エネルギー転移係数\nが、物質やエネルギーとどんな関係にあるかを公表データから明らかにし、より\n精度の高い両係数の算定に役立てたい。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"平岡, 武"}],"nameIdentifiers":[{"nameIdentifier":"444612","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤崎, 達也"}],"nameIdentifiers":[{"nameIdentifier":"444613","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原, 信幸"}],"nameIdentifiers":[{"nameIdentifier":"444614","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平岡 武","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444615","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原 信幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444616","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"光子の線量測定における質量エネルギー吸収係数と質量エネルギー転移係数の関係","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"光子の線量測定における質量エネルギー吸収係数と質量エネルギー転移係数の関係"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-01-29"},"publish_date":"2007-01-29","publish_status":"0","recid":"44779","relation_version_is_last":true,"title":["光子の線量測定における質量エネルギー吸収係数と質量エネルギー転移係数の関係"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:11:26.192626+00:00"}