{"created":"2023-05-15T14:34:36.187072+00:00","id":44716,"links":{},"metadata":{"_buckets":{"deposit":"7a81ecae-adc2-4632-8f90-b6175e9953c1"},"_deposit":{"created_by":1,"id":"44716","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44716"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044716","sets":["1"]},"author_link":["443946","443947","443945"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"678","bibliographicPageStart":"671","bibliographicVolumeNumber":"55","bibliographic_titles":[{"bibliographic_title":"Radioisotopes"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"モニタリングポストは,原子力施設における放射線および放射性物質の漏えい監視のために有用な装置である。この装置は空間線量率(μSv/h,nGy/h)や計数率(cpm,cps)のデータを定期的に提供するものである。我々はこのようなデータの他に原子力事故の早期の発見,あるいは異常データの的確な解釈に有用なγ線の飛来方向を計測できる新型のモニタリングポストを試作した。この検出器は,扇形をしたNaI(Tl),CsI(Tl),BGO の3種類のシンチレータと光電子増倍管より構成される。飛来方向によって,それぞれのシンチレータが作る光電ピークの計数が変化することを利用したものである。低エネルギーの241Am(60 keV),中エネルギーの133Ba(356 keV), 137Cs(662keV),高エネルギーの60Co(1250keV)を用いて,電磁カスケードモンテカルロシミュレーション(EGS),および実験によってエネルギー領域ごとの方向計測感度の特性を評価した。この結果,本検出器は広いエネルギー領域においてγ線の飛来方向を計測できることが確認された。","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0033-8303","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"白川, 芳幸"}],"nameIdentifiers":[{"nameIdentifier":"443945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"443946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白川 芳幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"443947","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"3種シンチレータによるモニタリングポストの方向計測特性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"3種シンチレータによるモニタリングポストの方向計測特性"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-11-22"},"publish_date":"2006-11-22","publish_status":"0","recid":"44716","relation_version_is_last":true,"title":["3種シンチレータによるモニタリングポストの方向計測特性"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:12:11.391926+00:00"}