{"created":"2023-05-15T14:34:18.158526+00:00","id":44349,"links":{},"metadata":{"_buckets":{"deposit":"7f1ef36c-f5f1-40e7-91c3-f122a4e76983"},"_deposit":{"created_by":1,"id":"44349","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44349"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044349","sets":["1"]},"author_link":["440590","440585","440587","440589","440592","440591","440583","440586","440582","440588","440584"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"191","bibliographicPageStart":"186","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"Acta Radiologica"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose: To investigate the feasibility of volumetric cine imaging in human cardiac studies, by comparing in vivo and in vitro coronary angiography using a 256-detector row CT without ECG gating.\n\\nMaterial and Methods: The left and right coronary arteries of two domestic pigs were scanned in vivo and in vitro in cine mode using the 256-detector row CT. The device scanned approximately 100 mm in the cranio-caudal direction with one rotation, with a slice thickness of 0.5 mm.\n\\nResults: The coronary arteries could be observed to the third-degree branches in vitro, but could be visualized clearly only to the proximal portion (first- or second-degree branches) in vivo. \n\\nConclusion: Application of cardiac volumetric cine imaging with 256-detector row CT appears a promising means of obtaining diagnostic information and has potential for adoption to human studies.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0284-1851","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Mori, Shinichiro"}],"nameIdentifiers":[{"nameIdentifier":"440582","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kondo, Chisato"}],"nameIdentifiers":[{"nameIdentifier":"440583","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuki, Naoki"}],"nameIdentifiers":[{"nameIdentifier":"440584","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kusakabe, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"440585","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"440586","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"440587","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 慎一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"440588","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"近藤 千里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"440589","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 直樹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"440590","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"日下部 正宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"440591","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遠藤 真広","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"440592","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-06-24"},"publish_date":"2006-06-24","publish_status":"0","recid":"44349","relation_version_is_last":true,"title":["Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:16:30.567804+00:00"}