{"created":"2023-05-15T14:34:02.554054+00:00","id":44121,"links":{},"metadata":{"_buckets":{"deposit":"f315454b-5ed1-47c9-8ce2-40d74af492fa"},"_deposit":{"created_by":1,"id":"44121","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44121"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044121","sets":["1"]},"author_link":["438545","438546","438547","438544"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"551","bibliographicPageStart":"547","bibliographicVolumeNumber":"255","bibliographic_titles":[{"bibliographic_title":"Journal of Radioanalytical and Nuclear Chemistry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In order to determine trace levels of rhenium in plant samples by ICP-MS, a pretreatment method was developed. Ten radish samples (Raphanus sativus L.) grown in solution culture containing 184ReO4- were used in this study. The samples were separated into three parts (leaves, fleshy root and fine roots) then each sample was oven-dried at 60C. The Re loss ratios in the samples after incineration at 450C for 3 h and acid leaching at 90C for 3 h were compared. There was no difference of recoveries among the sample parts, and throughout the procedure, almost 100% Re was recovered from the samples.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0236-5731","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"438544","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"438545","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438546","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438547","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Pretreatment of plant samples for the determination of rhenium by ICP-MS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Pretreatment of plant samples for the determination of rhenium by ICP-MS"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-05-31"},"publish_date":"2006-05-31","publish_status":"0","recid":"44121","relation_version_is_last":true,"title":["Pretreatment of plant samples for the determination of rhenium by ICP-MS"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:19:09.853821+00:00"}