{"created":"2023-05-15T14:34:02.067946+00:00","id":44114,"links":{},"metadata":{"_buckets":{"deposit":"2cdc1f00-8730-4831-935d-c2c894abfa10"},"_deposit":{"created_by":1,"id":"44114","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44114"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044114","sets":["1"]},"author_link":["438498","438497","438503","438501","438502","438496","438500","438494","438504","438495","438499"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"115","bibliographicPageStart":"112","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"胸部CT検診"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"CT検診条件下の撮影において、CT装置やその他要因の違いがCT値にどの様な影響を及ぼすのか、試作ファントムを用いて検討した。水、GGOを呈する小型肺腺癌の球形模擬腫瘍4タイブ、肺野を壊したコルク片、空気のCT値を、装置間、mAs値、再構成関数、被曝低減フィルタの有無で比較した。結果、CT値は同一装置においてmAs値、再構成関数の違いによる大きなCT値の差はなかったが、CT装置の違いによる差は明確であった。また、被曝低減フィルタの有無によるCT値の差も認められた。","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1341-8556","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"米田, 晃敏"}],"nameIdentifiers":[{"nameIdentifier":"438494","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岡本, 英明"}],"nameIdentifiers":[{"nameIdentifier":"438495","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂本, 正利"}],"nameIdentifiers":[{"nameIdentifier":"438496","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮崎, 正義"}],"nameIdentifiers":[{"nameIdentifier":"438497","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"黒田, 知純"}],"nameIdentifiers":[{"nameIdentifier":"438498","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 隆一郎"}],"nameIdentifiers":[{"nameIdentifier":"438499","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本, 徹"}],"nameIdentifiers":[{"nameIdentifier":"438500","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮本, 忠昭"}],"nameIdentifiers":[{"nameIdentifier":"438501","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"438502","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本 徹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438503","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮本 忠昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438504","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"CT検診条件におけるCT装置の特性比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"CT検診条件におけるCT装置の特性比較"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-05-30"},"publish_date":"2006-05-30","publish_status":"0","recid":"44114","relation_version_is_last":true,"title":["CT検診条件におけるCT装置の特性比較"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:19:14.590312+00:00"}