{"created":"2023-05-15T14:34:01.856894+00:00","id":44111,"links":{},"metadata":{"_buckets":{"deposit":"10db5d17-2ab0-4477-8096-f08d6856a41c"},"_deposit":{"created_by":1,"id":"44111","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44111"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044111","sets":["1"]},"author_link":["438472","438478","438480","438474","438473","438475","438479","438476","438481","438477"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"92","bibliographicPageStart":"88","bibliographicVolumeNumber":"570","bibliographic_titles":[{"bibliographic_title":"Analytica Chimica Acta"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A simple determination method for halogens (Cl, Br, and I) in plant samples using inductively coupled plasma mass spectrometry (ICP-MS) was developed. In order to extract these halogens into aqueous solution, a leaching step with tetramethyl ammonium hydroxide (TMAH) under mild conditions was carried out, i.e. a 0.1-g dried sample was left overnight (ca. 12 h) in contact with 1 mL of 25% TMAH in a small PFA vial at 60C. Then the sample was transferred to a 50-mL centrifuge tube and diluted to 50 mL with deionised water. After centrifugation, halogens in the supernatant were determined by ICP-MS. When standard reference materials were measured by the method, the data were within the 95% confidence range of the certified values. The results also agreed well with the values obtained by neutron activation analysis with correlation factor r>0.99.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0003-2670","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"438472","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"438473","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirai, Ikuko"}],"nameIdentifiers":[{"nameIdentifier":"438474","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsukada, Hirofumi"}],"nameIdentifiers":[{"nameIdentifier":"438475","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takeda, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"438476","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438477","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438478","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平井 育子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438479","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塚田 祥文","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438480","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田 洋","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"438481","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Determination of chlorine, bromine and iodine in plant samples by inductively coupled plasma-mass spectrometry after leaching with tetramethyl ammonium hydroxide under a mild temperature condition","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Determination of chlorine, bromine and iodine in plant samples by inductively coupled plasma-mass spectrometry after leaching with tetramethyl ammonium hydroxide under a mild temperature condition"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-05-30"},"publish_date":"2006-05-30","publish_status":"0","recid":"44111","relation_version_is_last":true,"title":["Determination of chlorine, bromine and iodine in plant samples by inductively coupled plasma-mass spectrometry after leaching with tetramethyl ammonium hydroxide under a mild temperature condition"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:19:16.889027+00:00"}