@article{oai:repo.qst.go.jp:00044111, author = {Tagami, Keiko and Uchida, Shigeo and Hirai, Ikuko and Tsukada, Hirofumi and Takeda, Hiroshi and 田上 恵子 and 内田 滋夫 and 平井 育子 and 塚田 祥文 and 武田 洋}, issue = {1}, journal = {Analytica Chimica Acta}, month = {Jun}, note = {A simple determination method for halogens (Cl, Br, and I) in plant samples using inductively coupled plasma mass spectrometry (ICP-MS) was developed. In order to extract these halogens into aqueous solution, a leaching step with tetramethyl ammonium hydroxide (TMAH) under mild conditions was carried out, i.e. a 0.1-g dried sample was left overnight (ca. 12 h) in contact with 1 mL of 25% TMAH in a small PFA vial at 60C. Then the sample was transferred to a 50-mL centrifuge tube and diluted to 50 mL with deionised water. After centrifugation, halogens in the supernatant were determined by ICP-MS. When standard reference materials were measured by the method, the data were within the 95% confidence range of the certified values. The results also agreed well with the values obtained by neutron activation analysis with correlation factor r>0.99.}, pages = {88--92}, title = {Determination of chlorine, bromine and iodine in plant samples by inductively coupled plasma-mass spectrometry after leaching with tetramethyl ammonium hydroxide under a mild temperature condition}, volume = {570}, year = {2006} }