{"created":"2023-05-15T14:33:49.445224+00:00","id":43877,"links":{},"metadata":{"_buckets":{"deposit":"376d1d6d-4e5c-4550-bc6a-4f168183933f"},"_deposit":{"created_by":1,"id":"43877","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"43877"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00043877","sets":["1"]},"author_link":["436243","436240","436241","436242"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"144","bibliographicPageStart":"140","bibliographicVolumeNumber":"155","bibliographic_titles":[{"bibliographic_title":"Journal of Magnetic Resonance"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Continuous-wave EPR spectroscopy using a frequency modulation (FM) scheme was developed. An electronically tunable resonator and an automatic tuning control (ATC) system were used. Using the FM scheme instead of magnetic field modulation, we detected EPR absorption at the first derivative mode. We used a microwave frequency of 1.1 GHz in the present experiment. Similar signal-to-noise ratios were obtained with conventional field modulation and the FM method, and a low-quality factor EPR resonator was not necessary to suppress the significant microwave reflection from the resonator. The FM method with a tunable resonator may be an alternative solution to achieving phase-sensitive detection, when the side-effects of magnetic field modulation, such as microphonic noise and mechanical vibration, are detrimental for EPR detection. (c) 2002 Elsevier Science (USA).","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1090-7807","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hirata, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"436240","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ono, Mitsuhiro"}],"nameIdentifiers":[{"nameIdentifier":"436241","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"436242","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小野 光弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"436243","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"1.1-GHz continuous-wave EPR spectroscopy with a frequency modulation method.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"1.1-GHz continuous-wave EPR spectroscopy with a frequency modulation method."}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-12-14"},"publish_date":"2005-12-14","publish_status":"0","recid":"43877","relation_version_is_last":true,"title":["1.1-GHz continuous-wave EPR spectroscopy with a frequency modulation method."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:22:01.175550+00:00"}