{"created":"2023-05-15T14:33:45.401954+00:00","id":43789,"links":{},"metadata":{"_buckets":{"deposit":"b70f9f7a-1c22-44ed-8874-bdf14559ff9c"},"_deposit":{"created_by":1,"id":"43789","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"43789"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00043789","sets":["1"]},"author_link":["435364","435365","435371","435363","435368","435369","435370","435367","435362","435366"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"161","bibliographicPageStart":"157","bibliographicVolumeNumber":"79","bibliographic_titles":[{"bibliographic_title":"日大歯学"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"摂食嚥下が困難な患者に対して、造影剤を含む液体または半固形・固形物を被験者に飲食させ、口への取り込みから嚥下の終了までの動態をX線透視装置と録画装置を用い記録・観察する方法にビデオ嚥下造営検査(Videofluorography,以下VF)がある。今回我々の行っているVF検査に伴う被曝線量について報告する。使用したX線透視装置はClearscope(Model SXT9000A,\n東芝)である。ファントムはX線人体等価のWoman Rando Phantom(Alderson)を使用した。測定にはUD-170A(BeO)およびUD-110S(Ca2SO4)(Panasonic)の熱蛍光線量計(TLD)を用いた。測定対象とした組織・臓器は生殖腺、赤色骨髄、甲状腺、肺、胃、結腸、肝臓、食道、膀胱、乳房、皮膚、脳、胸腺、副腎、腎臓、脾臓、膵臓、小腸、上部大腸、子宮、唾液腺(耳下腺・顎下腺、舌下腺)および水晶体であり、それぞれについて被曝線量を測定した。結果は以下のようであった。1.VF検査時の照射野","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-0102","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩井, 一男"}],"nameIdentifiers":[{"nameIdentifier":"435362","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本, 光二"}],"nameIdentifiers":[{"nameIdentifier":"435363","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"澤田, 久仁彦"}],"nameIdentifiers":[{"nameIdentifier":"435364","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本, 邦史"}],"nameIdentifiers":[{"nameIdentifier":"435365","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"里見, 智恵子"}],"nameIdentifiers":[{"nameIdentifier":"435366","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"生木, 俊輔"}],"nameIdentifiers":[{"nameIdentifier":"435367","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本, 光彦"}],"nameIdentifiers":[{"nameIdentifier":"435368","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西澤, かな枝"}],"nameIdentifiers":[{"nameIdentifier":"435369","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩井 一男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"435370","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西澤 かな枝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"435371","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ビデオ嚥下造影検査時の被曝線量","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ビデオ嚥下造影検査時の被曝線量"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-08-31"},"publish_date":"2005-08-31","publish_status":"0","recid":"43789","relation_version_is_last":true,"title":["ビデオ嚥下造影検査時の被曝線量"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:23:02.492912+00:00"}