{"created":"2023-05-15T14:33:27.674112+00:00","id":43397,"links":{},"metadata":{"_buckets":{"deposit":"396b9c9d-abef-48ff-89a0-58eea840858d"},"_deposit":{"created_by":1,"id":"43397","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"43397"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00043397","sets":["1"]},"author_link":["431640","431644","431654","431650","431648","431658","431656","431649","431639","431652","431638","431643","431646","431641","431653","431651","431642","431645","431655","431657","431647"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"326","bibliographicPageStart":"321","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"Standards and Codes of Practice in Medical Radiation Dosimetry (IAEA Proceedings Series)"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A new protocol for dosimetry in external beam radiotherapy was published by the\nJapan Society of Medical Physics in September 2002.The protocol deals with proton and\nheavy ion beams and with electron and photon beams, using the absorbed dose to water\nformalism with calculated ND,w factors. An intercomparison programme was carried out\nwith the new protocol to establish interinstitutional uniformity in proton beam\ndosimetry. The absorbed doses were measured with different cylindrical ionization\nchambers in a water phantom at a position of 30 mm residual range for a proton beam\nthat had a range of 155 mm and a spread out Bragg peak 60 mm wide. As a result, the\nintercomparison showed that the use of the new protocol would improve the +/-1.0%\n(one standard deviation) and 2.7% (maximum discrepancy) differences in absorbed\ndoses stated by the participating institutions to +/-0.3% and 0.9%, respectively. The new protocol will be adopted by all the participants.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"International Atomic Energy Agency"}]},"item_8_relation_10":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"9-2011-1403","subitem_relation_type_select":"ISBN"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fukumura, Akifumi"}],"nameIdentifiers":[{"nameIdentifier":"431638","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"431639","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"431640","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yusa, Ken"}],"nameIdentifiers":[{"nameIdentifier":"431641","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Maruhashi, Akira"}],"nameIdentifiers":[{"nameIdentifier":"431642","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nohtomi, Akihiro"}],"nameIdentifiers":[{"nameIdentifier":"431643","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishio, Teiji"}],"nameIdentifiers":[{"nameIdentifier":"431644","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinbo, Munefumi"}],"nameIdentifiers":[{"nameIdentifier":"431645","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akagi, Takashi"}],"nameIdentifiers":[{"nameIdentifier":"431646","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yanou, Toshihiro"}],"nameIdentifiers":[{"nameIdentifier":"431647","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukuda, Shigekazu"}],"nameIdentifiers":[{"nameIdentifier":"431648","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村 明史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431649","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431650","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"兼松 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431651","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遊佐 顕","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431652","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"丸橋 晃","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431653","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"納冨 昭弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431654","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西尾 禎治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431655","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"新保 宗史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431656","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤城 卓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431657","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福田 茂一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"431658","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Proton beam dosimetry:Protocol and intercomparison in Japan","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Proton beam dosimetry:Protocol and intercomparison in Japan"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-05-27"},"publish_date":"2004-05-27","publish_status":"0","recid":"43397","relation_version_is_last":true,"title":["Proton beam dosimetry:Protocol and intercomparison in Japan"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:27:48.418376+00:00"}